Lennox Furnace: Two horizontal lines on display (soft disable) – Lennox communicating
Two horizontal lines on display (soft disable) - Lennox communicating on a Lennox furnace: The control shows two horizontal lines on its 7-segment display (damper module or EIM: green LED 3 s on / 1 s off). The thermostat found a device it does not recognize and put it in soft disable; the thermostat itself shows no alert code for this (often alert 10 is logged).
Applies to: Lennox communicating gas furnaces (e.g. SL280UHV/SL280UHNV, EL296UHV) in S30/S40 smart thermostat systems
Common causes of two horizontal lines on display (soft disable) - lennox communicating
- Control board was replaced and the system was not reconfigured
- New device added after commissioning
- Device on the bus not communicating with the thermostat
How to fix two horizontal lines on display (soft disable) - lennox communicating: step by step
- Confirm wiring between all devices (thermostat/smart hub, indoor, outdoor, damper module, EIM).
- Cycle power to the control that shows the soft disable.
- Reconfigure. S30: go to Menu > Settings > Advanced Settings, open View Dealer Control Center, then Equipment > Reset All Equipment. S40: go to Menu > Settings > Advanced Settings, open View Service Support Center, then Equipment Setting > Reset and pick Reset HVAC Equipment.
- Run the thermostat setup again so it auto-detects every device.
- Check the device's installation/setup guide if it stays disabled.
If the unit shows an error code, look it up: Lennox Furnace codes
Models
Lennox EL195UHNE
EL195UH040NE36BEL195UH060NE36BEL195UH080NE48CEL195UH100NE60C
EL296UHV
EL296UH045XV36BEL296UH070XV36BEL296UH090XV36CEL296UH090XV48CEL296UH090XV60CEL296UH110XV48CEL296UH110XV60CEL296UH135XV60D
Lennox G43UF
G43UF-24B-045G43UF-24B-070G43UF-36B-070G43UF-36C-090G43UF-36C-090HG43UF-48C-090G43UF-48C-110G43UF-48C-110HG43UF-60C-110G43UF-60D-135
Lennox ML180UHE
ML180UH045E36AKML180UH045XE36AKML180UH070E36AKML180UH070E36BKML180UH070XE36AKML180UH070XE36BKML180UH090E48BKML180UH090E60CKML180UH090XE48BKML180UH110E60CKML180UH110XE60CKML180UH135E60DK
Lennox SL280UHV
SL280UH060NV36ASL280UH070V36ASL280UH080NV48BSL280UH080NV60CSL280UH090V36BSL280UH090V48BSL280UH090V60CSL280UH100NV60CSL280UH110V60CSL280UH135V60D
Lennox SL297NV
SL297UH040NV36BSL297UH060NV36BSL297UH080NV48CSL297UH080NV60C
Source: Lennox Alert Code Guide (V2) 100017, 3. Soft Disable, p.6; Lennox SL280UHNV Unit Information Corp 1601-L8 (rev 04/2024), Soft Disable, p.15. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.