Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Lennox Furnace: Two horizontal lines on display (soft disable) – Lennox communicating

Updated · by Aurora Star Tech Inc.

Two horizontal lines on display (soft disable) - Lennox communicating on a Lennox furnace: The control shows two horizontal lines on its 7-segment display (damper module or EIM: green LED 3 s on / 1 s off). The thermostat found a device it does not recognize and put it in soft disable; the thermostat itself shows no alert code for this (often alert 10 is logged).

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Lennox communicating gas furnaces (e.g. SL280UHV/SL280UHNV, EL296UHV) in S30/S40 smart thermostat systems

Common causes of two horizontal lines on display (soft disable) - lennox communicating

  • Control board was replaced and the system was not reconfigured
  • New device added after commissioning
  • Device on the bus not communicating with the thermostat

How to fix two horizontal lines on display (soft disable) - lennox communicating: step by step

  1. Confirm wiring between all devices (thermostat/smart hub, indoor, outdoor, damper module, EIM).
  2. Cycle power to the control that shows the soft disable.
  3. Reconfigure. S30: go to Menu > Settings > Advanced Settings, open View Dealer Control Center, then Equipment > Reset All Equipment. S40: go to Menu > Settings > Advanced Settings, open View Service Support Center, then Equipment Setting > Reset and pick Reset HVAC Equipment.
  4. Run the thermostat setup again so it auto-detects every device.
  5. Check the device's installation/setup guide if it stays disabled.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Lennox Furnace codes

Models

Lennox EL195UHNE

EL195UH040NE36BEL195UH060NE36BEL195UH080NE48CEL195UH100NE60C

EL296UHV

EL296UH045XV36BEL296UH070XV36BEL296UH090XV36CEL296UH090XV48CEL296UH090XV60CEL296UH110XV48CEL296UH110XV60CEL296UH135XV60D

Lennox G43UF

G43UF-24B-045G43UF-24B-070G43UF-36B-070G43UF-36C-090G43UF-36C-090HG43UF-48C-090G43UF-48C-110G43UF-48C-110HG43UF-60C-110G43UF-60D-135

Lennox ML180UHE

ML180UH045E36AKML180UH045XE36AKML180UH070E36AKML180UH070E36BKML180UH070XE36AKML180UH070XE36BKML180UH090E48BKML180UH090E60CKML180UH090XE48BKML180UH110E60CKML180UH110XE60CKML180UH135E60DK

Lennox SL280UHV

SL280UH060NV36ASL280UH070V36ASL280UH080NV48BSL280UH080NV60CSL280UH090V36BSL280UH090V48BSL280UH090V60CSL280UH100NV60CSL280UH110V60CSL280UH135V60D

Lennox SL297NV

SL297UH040NV36BSL297UH060NV36BSL297UH080NV48CSL297UH080NV60C

Source: Lennox Alert Code Guide (V2) 100017, 3. Soft Disable, p.6; Lennox SL280UHNV Unit Information Corp 1601-L8 (rev 04/2024), Soft Disable, p.15. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977