Goodman Air Handler error codes list

CodeMeaningSeverity
1ACCompressor cooling, low stage (non-comm)Low
2aCCompressor cooling, high stage (non-comm)Low
5rShared data revisionLow
ACCompressor cooling, single stage (non-comm)Low
AC1Compressor cooling, low stage (comm)Low
AC2Compressor cooling, high stage (comm)Low
AxxAirflow readout (A08 = 800 CFM)Low
CrControl firmware revisionLow
df1Defrost, low-stage electric heatLow
df2Defrost, high-stage electric heatLow
dftDefrost, single-stage electric heat (non-comm)Low
dHUDehumidificationLow
E05Air handler fuse openHigh
Eb0Blower motor not running with a demand presentHigh
Eb1Control lost communication with the blower motorHigh
Eb2Motor horsepower does not match shared dataHigh
Eb4Blower motor lost rotor control or high currentHigh
Eb5Blower motor failed to start 10 timesHigh
Eb6Blower shut down for voltage or power module temperatureHigh
Eb7Blower motor missing shared data / failed to start 40 timesHigh
Eb9Airflow lower than demandedMedium
EC1Communication error with the outdoor unitHigh
Ed1Invalid shared dataHigh
Ed4Shared data rejected by the controlHigh
FAnConstant fanLow
FCLFault recall (outdoor communicating units)Low
Flashing optionMenu option flashing = not yet selectedLow
HPCompressor heat, single stageLow
HP1Compressor heat, low stage (comm)Low
HP2Compressor heat, high stage (comm)Low
HtElectric heat, single stageLow
Ht1Electric heat (Ht1)Low
Ht2Electric heat, high stageLow
IdlIdle - no callLow
L6FFault recall (furnace-type menu)Low
LrnRestart indoor-outdoor communicationLow
RDS 4 flashesR32 sensor internal faultHigh
RDS fast flashR-32 leak alarm (or system verification test)Critical
RDS slow flashNormal operation - leak detection OKLow
RDS steady onDelay mode after leak alarm or faultMedium
RDS test modeSystem verification test (simulated leak)Low
Rx LED rapid flashGreen receive LED rapid flashing - normal network trafficLow

Find codes by Goodman model

Goodman/Amana R-32 AMST/AWSF/ACSF air handlers

ACSF****13**AAAMST***U1300AAAWSF****13**AAAWST****13**AA

Goodman/Amana ComfortBridge AVPTC/MBVC

AVPTC25B14AVPTC29B14AVPTC31C14AVPTC31C14ADAVPTC33C14AVPTC35B14AVPTC37B14AVPTC37C14AVPTC37D14AVPTC39C14AVPTC49C14AVPTC49D14AVPTC59C14AVPTC59D14AVPTC61D14AVPTC183014AVPTC313714AVPTC426014MBVC1201MBVC1601MBVC2001

Air Handler troubleshooting guides

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.