No electric heat - R-32 air handler heat kit on a Goodman air handler: Heat strips do not come on during an auxiliary/emergency heat call.

Homeowner with a air handler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: R-32 AMST, AWSF/AWST, ACSF air handlers with electric heat kits

Common causes of no electric heat - r-32 air handler heat kit

  • No line voltage to the air handler or heat kit
  • Transformer failure
  • No W signal from the thermostat
  • Contactor/sequencer not closing
  • Open fusible link
  • Open heater element
  • Open limit switch

How to fix no electric heat - r-32 air handler heat kit: step by step

  1. Check 240 V at the air handler panel; if missing check breakers or fuses and the wiring.
  2. Check 24 V at the transformer secondary; replace the transformer if missing.
  3. Check 24 V on W at the heat contactor; none = thermostat or wiring.
  4. Confirm the contactor(s) close; replace if not. Check line voltage at the contactor(s).
  5. Power off: check each fusible link (opens at about 333 F) - find why it opened before replacing; never bypass.
  6. Ohm each heat element; replace open elements.
  7. Check limit switches (open at about 150 F); replace an open limit and look for low airflow.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Goodman Air Handler codes

Models

Goodman/Amana R-32 AMST/AWSF/ACSF air handlers

ACSF****13**AAAMST***U1300AAAWSF****13**AAAWST****13**AA

Goodman/Amana ComfortBridge AVPTC/MBVC

AVPTC25B14AVPTC29B14AVPTC31C14AVPTC31C14ADAVPTC33C14AVPTC35B14AVPTC37B14AVPTC37C14AVPTC37D14AVPTC39C14AVPTC49C14AVPTC49D14AVPTC59C14AVPTC59D14AVPTC61D14AVPTC183014AVPTC313714AVPTC426014MBVC1201MBVC1601MBVC2001

Source: Goodman RS6200301 R-32 GLXS/ALXS/GLZS/ALZS service (07-2024), Auxiliary Electric Heating flowchart p.48; heater limit/fuse link checks p.34. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Air Handler Emergency

647-657-2977