Goodman Error Code 2aC: Compressor cooling, high stage (non-comm) (Air Handler)

Updated · by Aurora Star Tech Inc.

Goodman error code 2aC on a air handler means: Compressor cooling, high stage (non-comm). It is also called Goodman diagnostic code 2aC.

Low severityAir HandlerGoodman/Amana ComfortBridge AVPTC/MBVC

Homeowner? What Goodman code 2aC means for you

Usually minor Your air handler is reporting: Compressor cooling, high stage (non-comm). This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Goodman error code 2aC mean?

Shown during a high-stage cooling call with a two-stage non-communicating outdoor unit.

Applies to: AVPTC / MBVC ComfortBridge air handlers

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Goodman models that use code 2aC

Show all 21 models

AVPTC25B14AVPTC29B14AVPTC31C14AVPTC31C14ADAVPTC33C14AVPTC35B14AVPTC37B14AVPTC37C14AVPTC37D14AVPTC39C14AVPTC49C14AVPTC49D14AVPTC59C14AVPTC59D14AVPTC61D14AVPTC183014AVPTC313714AVPTC426014MBVC1201MBVC1601MBVC2001

Other Goodman Air Handler codes

CodeMeaning
1ACCompressor cooling, low stage (non-comm)
5rShared data revision
ACCompressor cooling, single stage (non-comm)
AC1Compressor cooling, low stage (comm)
AC2Compressor cooling, high stage (comm)
AxxAirflow readout (A08 = 800 CFM)
CrControl firmware revision
df1Defrost, low-stage electric heat
df2Defrost, high-stage electric heat
dftDefrost, single-stage electric heat (non-comm)
dHUDehumidification
E0FCondensate switch open - high water in drain pan

All Goodman Air Handler error codes →

Goodman code 2aC: homeowner questions

What does Goodman code 2aC mean?

Compressor cooling, high stage (non-comm). Shown during a high-stage cooling call with a two-stage non-communicating outdoor unit.

Is it safe to keep using my air handler with code 2aC?

Usually yes. Code 2aC is normally minor, but if it keeps coming back have it checked.

Can I reset Goodman code 2aC myself?

You can try one reset (power off for 30 seconds, then on). If Goodman code 2aC comes back, the cause is still there and a licensed technician should check it.

Who can fix Goodman code 2aC near me?

Aurora Star Tech Inc. repairs Goodman air handlers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Troubleshooting guides

Source: Goodman ComfortNet ASXC-DSXC-GSXC / ASZC-DSZC-GSZC / AVPTC-MBVC service, Air Handler Display (B*) system status table p.63. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.