Goodman Air Handler: Blower not running – R-32 AMST/AWSF EEM air handler

Updated · by Aurora Star Tech Inc.

Blower not running - R-32 AMST/AWSF EEM air handler on a Goodman air handler: Indoor blower (EEM/constant-torque motor) does not start on a fan, cooling or heat call.

Homeowner with a air handler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: R-32 AMST, AWSF/AWST, ACSF air handlers with EEM blower

Common causes of blower not running - r-32 amst/awsf eem air handler

  • No 240 V at the motor
  • No 24 V signal to a motor tap
  • Failed motor or motor module

How to fix blower not running - r-32 amst/awsf eem air handler: step by step

  1. WARNING: Disconnect power before handling motor connectors.
  2. Measure about 240 V across L and N at the motor; if missing, check breaker, fuses and wiring.
  3. Measure 24 V from C to the active speed tap (T1-T5 / T6-T9 or 1-5 depending on model); if missing, confirm the thermostat is calling for fan and check the low-voltage fuse and wiring.
  4. With both line voltage and 24 V present and no rotation, the motor (or its module) has failed - replace it.
  5. When fitting a new motor, keep the belly band clear of the motor vents and form a drip loop in the wiring.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Goodman Air Handler codes

Models

Goodman/Amana R-32 AMST/AWSF/ACSF air handlers

ACSF****13**AAAMST***U1300AAAWSF****13**AAAWST****13**AA

Goodman/Amana ComfortBridge AVPTC/MBVC

AVPTC25B14AVPTC29B14AVPTC31C14AVPTC31C14ADAVPTC33C14AVPTC35B14AVPTC37B14AVPTC37C14AVPTC37D14AVPTC39C14AVPTC49C14AVPTC49D14AVPTC59C14AVPTC59D14AVPTC61D14AVPTC183014AVPTC313714AVPTC426014MBVC1201MBVC1601MBVC2001

Source: Goodman RS6200301 R-32 GLXS/ALXS/GLZS/ALZS service (07-2024), Air Handler EEM Motor flowchart p.47; Checking High Efficiency Motors p.27. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.