Goodman Error Code RDS steady on: Delay mode after leak alarm or fault (Air Handler)
Goodman error code RDS steady on on a air handler means: Delay mode after leak alarm or fault. It is also called Goodman diagnostic code RDS steady on.
Homeowner? What Goodman code RDS steady on means for you
Check, then call Your air handler is reporting: Delay mode after leak alarm or fault. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Goodman error code RDS steady on mean?
Red LED on steady: the alarm or fault has cleared but the board stays in mitigation (blower on) for 5 minutes before going back to normal.
Applies to: R-32 air handlers with refrigerant detection system (A2L PCB + R32 sensor): AMST, AWSF/AWST, ACSF
Common causes of Goodman code RDS steady on
- Recent leak alarm or board/sensor fault
Goodman models that use code RDS steady on
ACSF****13**AAAMST***U1300AAAWSF****13**AAAWST****13**AA
Other Goodman Air Handler codes
All Goodman Air Handler error codes →
Goodman code RDS steady on: homeowner questions
What does Goodman code RDS steady on mean?
Delay mode after leak alarm or fault. Red LED on steady: the alarm or fault has cleared but the board stays in mitigation (blower on) for 5 minutes before going back to normal.
Is it safe to keep using my air handler with code RDS steady on?
It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.
Can I reset Goodman code RDS steady on myself?
You can try one reset (power off for 30 seconds, then on). If Goodman code RDS steady on comes back, the cause is still there and a licensed technician should check it.
Who can fix Goodman code RDS steady on near me?
Aurora Star Tech Inc. repairs Goodman air handlers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Troubleshooting guides
- Air filter replacement and service interval All brands · Air Handler
- Cold-weather freeze protection when system is off All brands · Air Handler
- Condensate drain check All brands · Air Handler
- Disconnect power before opening access panels All brands · Air Handler
- Indoor humidity above 60% RH All brands · Air Handler
- Insufficient heating or cooling All brands · Air Handler
- No heating or cooling, blower does not run All brands · Air Handler
- System fails to operate All brands · Air Handler
Source: Goodman RS6200301 R-32 GLXS/ALXS/GLZS/ALZS service (07-2024), A2L PCB Fault Code and Recommended Action table p.25-26. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.