Goodman Error Code Eb6: Blower shut down for voltage or power module temperature (Air Handler)

Updated · by Aurora Star Tech Inc.

Goodman error code Eb6 on a air handler means: Blower shut down for voltage or power module temperature. It is also called Goodman diagnostic code Eb6.

High severityAir HandlerGoodman/Amana ComfortBridge AVPTC/MBVC

Homeowner? What Goodman code Eb6 means for you

Call a technician Your air handler is reporting: Blower shut down for voltage or power module temperature. The air handler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Goodman error code Eb6 mean?

The motor shut down because of over or under voltage, or because its power module overheated.

Applies to: ComfortBridge communicating air handlers AVPTC**14 (B* revision board) and MBVC1201/1601/2001 modular blowers

Common causes of Goodman code Eb6

  • Line voltage to the air handler too high or too low
  • High ambient temperature
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Goodman models that use code Eb6

Show all 21 models

AVPTC25B14AVPTC29B14AVPTC31C14AVPTC31C14ADAVPTC33C14AVPTC35B14AVPTC37B14AVPTC37C14AVPTC37D14AVPTC39C14AVPTC49C14AVPTC49D14AVPTC59C14AVPTC59D14AVPTC61D14AVPTC183014AVPTC313714AVPTC426014MBVC1201MBVC1601MBVC2001

Other Goodman Air Handler codes

CodeMeaning
Eb0Blower motor not running with a demand present
Eb1Control lost communication with the blower motor
Eb2Motor horsepower does not match shared data
Eb3Blower limiting on power, temperature or speed
Eb4Blower motor lost rotor control or high current
Eb5Blower motor failed to start 10 times
Eb7Blower motor missing shared data / failed to start 40 times
Eb9Airflow lower than demanded
EC1Communication error with the outdoor unit
Ed0No shared data on the network
Ed1Invalid shared data
Ed4Shared data rejected by the control

All Goodman Air Handler error codes →

Goodman code Eb6: homeowner questions

What does Goodman code Eb6 mean?

Blower shut down for voltage or power module temperature. The motor shut down because of over or under voltage, or because its power module overheated.

Is it safe to keep using my air handler with code Eb6?

It depends on the cause. The air handler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Goodman code Eb6 myself?

You can try one reset (power off for 30 seconds, then on). If Goodman code Eb6 comes back, the cause is still there and a licensed technician should check it.

Who can fix Goodman code Eb6 near me?

Aurora Star Tech Inc. repairs Goodman air handlers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Troubleshooting guides

Source: Goodman ComfortNet ASXC/GSXC/DSXC, ASZC/GSZC/DSZC, AVPTC/MBVC service manual, Air Handler Troubleshooting Matrix (B*) p.59-60. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.