Goodman Error Code Eb5: Blower motor failed to start 10 times (Air Handler)
Goodman error code Eb5 on a air handler means: Blower motor failed to start 10 times. It is also called Goodman diagnostic code Eb5.
Homeowner? What Goodman code Eb5 means for you
Call a technician Your air handler is reporting: Blower motor failed to start 10 times. The air handler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Goodman error code Eb5 mean?
The blower failed to start 10 times in a row.
Applies to: ComfortBridge communicating air handlers AVPTC**14 (B* revision board) and MBVC1201/1601/2001 modular blowers
Common causes of Goodman code Eb5
- Obstruction in the blower housing
- Seized motor bearings
- Failed blower motor
Goodman models that use code Eb5
Show all 21 models
AVPTC25B14AVPTC29B14AVPTC31C14AVPTC31C14ADAVPTC33C14AVPTC35B14AVPTC37B14AVPTC37C14AVPTC37D14AVPTC39C14AVPTC49C14AVPTC49D14AVPTC59C14AVPTC59D14AVPTC61D14AVPTC183014AVPTC313714AVPTC426014MBVC1201MBVC1601MBVC2001
Other Goodman Air Handler codes
All Goodman Air Handler error codes →
Goodman code Eb5: homeowner questions
What does Goodman code Eb5 mean?
Blower motor failed to start 10 times. The blower failed to start 10 times in a row.
Is it safe to keep using my air handler with code Eb5?
It depends on the cause. The air handler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Can I reset Goodman code Eb5 myself?
You can try one reset (power off for 30 seconds, then on). If Goodman code Eb5 comes back, the cause is still there and a licensed technician should check it.
Who can fix Goodman code Eb5 near me?
Aurora Star Tech Inc. repairs Goodman air handlers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Troubleshooting guides
- Blower not running - R-32 AMST/AWSF EEM air handler Goodman · Air Handler
- No electric heat - R-32 air handler heat kit Goodman · Air Handler
- Outdoor unit not communicating - ComfortBridge AVPTC/MBVC Goodman · Air Handler
Source: Goodman ComfortNet ASXC/GSXC/DSXC, ASZC/GSZC/DSZC, AVPTC/MBVC service manual, Air Handler Troubleshooting Matrix (B*) p.59-60. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.