Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Goodman Error Code Ht: Electric heat, single stage (Air Handler)

Updated · by Aurora Star Tech Inc.

Goodman error code Ht on a air handler means: Electric heat, single stage. It is also called Goodman diagnostic code Ht.

Low severityAir HandlerGoodman/Amana ComfortBridge AVPTC/MBVC

Homeowner? What Goodman code Ht means for you

Usually minor Your air handler is reporting: Electric heat, single stage. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Goodman error code Ht mean?

Shown while the electric heater kit is running on a single stage.

Applies to: AVPTC / MBVC ComfortBridge air handlers

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Goodman models that use code Ht

Show all 21 models

AVPTC25B14AVPTC29B14AVPTC31C14AVPTC31C14ADAVPTC33C14AVPTC35B14AVPTC37B14AVPTC37C14AVPTC37D14AVPTC39C14AVPTC49C14AVPTC49D14AVPTC59C14AVPTC59D14AVPTC61D14AVPTC183014AVPTC313714AVPTC426014MBVC1201MBVC1601MBVC2001

Other Goodman Air Handler codes

CodeMeaning
FAnConstant fan
FCLFault recall (outdoor communicating units)
Flashing optionMenu option flashing = not yet selected
HPCompressor heat, single stage
HP1Compressor heat, low stage (comm)
HP2Compressor heat, high stage (comm)
Ht1Electric heat (Ht1)
Ht2Electric heat, high stage
IdlIdle - no call
L6FFault recall (furnace-type menu)
LrnRestart indoor-outdoor communication
RDS 2 flashesControl board internal fault (leak detection board)

All Goodman Air Handler error codes →

Goodman code Ht: homeowner questions

What does Goodman code Ht mean?

Electric heat, single stage. Shown while the electric heater kit is running on a single stage.

Is it safe to keep using my air handler with code Ht?

Usually yes. Code Ht is normally minor, but if it keeps coming back have it checked.

Can I reset Goodman code Ht myself?

You can try one reset (power off for 30 seconds, then on). If Goodman code Ht comes back, the cause is still there and a licensed technician should check it.

Who can fix Goodman code Ht near me?

Aurora Star Tech Inc. repairs Goodman air handlers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Troubleshooting guides

Source: Goodman ComfortNet ASXC-DSXC-GSXC / ASZC-DSZC-GSZC / AVPTC-MBVC service, Air Handler Display (B*) system status table p.63. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Air Handler Emergency

647-657-2977