Goodman Error Code Axx: Airflow readout (A08 = 800 CFM) (Air Handler)
Goodman error code Axx on a air handler means: Airflow readout (A08 = 800 CFM). It is also called Goodman diagnostic code Axx.
Homeowner? What Goodman code Axx means for you
Usually minor Your air handler is reporting: Airflow readout (A08 = 800 CFM). This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Goodman error code Axx mean?
The display can show the estimated airflow as a letter A and two digits, for example A08 for 800 CFM. The manual also says airflow is shown rounded to the nearest 100 CFM and alternates with the system status.
Applies to: AVPTC / MBVC ComfortBridge air handlers
Goodman models that use code Axx
Show all 21 models
AVPTC25B14AVPTC29B14AVPTC31C14AVPTC31C14ADAVPTC33C14AVPTC35B14AVPTC37B14AVPTC37C14AVPTC37D14AVPTC39C14AVPTC49C14AVPTC49D14AVPTC59C14AVPTC59D14AVPTC61D14AVPTC183014AVPTC313714AVPTC426014MBVC1201MBVC1601MBVC2001
Other Goodman Air Handler codes
All Goodman Air Handler error codes →
Goodman code Axx: homeowner questions
What does Goodman code Axx mean?
Airflow readout (A08 = 800 CFM). The display can show the estimated airflow as a letter A and two digits, for example A08 for 800 CFM. The manual also says airflow is shown rounded to the nearest 100 CFM and alternates with the system status.
Is it safe to keep using my air handler with code Axx?
Usually yes. Code Axx is normally minor, but if it keeps coming back have it checked.
Can I reset Goodman code Axx myself?
You can try one reset (power off for 30 seconds, then on). If Goodman code Axx comes back, the cause is still there and a licensed technician should check it.
Who can fix Goodman code Axx near me?
Aurora Star Tech Inc. repairs Goodman air handlers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Troubleshooting guides
- Blower not running - R-32 AMST/AWSF EEM air handler Goodman · Air Handler
- No electric heat - R-32 air handler heat kit Goodman · Air Handler
- Outdoor unit not communicating - ComfortBridge AVPTC/MBVC Goodman · Air Handler
- Restart indoor-outdoor communication (Lrn) Goodman · Air Handler
- Run the R-32 leak alarm test (RDS test mode) Goodman · Air Handler
- View and clear the 6 most recent faults (FCL / L6F) Goodman · Air Handler
Source: Goodman ComfortNet ASXC-DSXC-GSXC / ASZC-DSZC-GSZC / AVPTC-MBVC service, ComfortBridge Technology Air Handler, Features p.43 and Circulator Blower Speed p.46. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.