Goodman AVPTC49D14 error codes list

CodeMeaningSeverity
1ACCompressor cooling, low stage (non-comm)Low
2aCCompressor cooling, high stage (non-comm)Low
5rShared data revisionLow
ACCompressor cooling, single stage (non-comm)Low
AC1Compressor cooling, low stage (comm)Low
AC2Compressor cooling, high stage (comm)Low
AxxAirflow readout (A08 = 800 CFM)Low
CrControl firmware revisionLow
df1Defrost, low-stage electric heatLow
df2Defrost, high-stage electric heatLow
dftDefrost, single-stage electric heat (non-comm)Low
dHUDehumidificationLow
E0FCondensate switch open - high water in drain panMedium
E05Air handler fuse openHigh
Eb0Blower motor not running with a demand presentHigh
Eb1Control lost communication with the blower motorHigh
Eb2Motor horsepower does not match shared dataHigh
Eb3Blower limiting on power, temperature or speedMedium
Eb4Blower motor lost rotor control or high currentHigh
Eb5Blower motor failed to start 10 timesHigh
Eb6Blower shut down for voltage or power module temperatureHigh
Eb7Blower motor missing shared data / failed to start 40 timesHigh
Eb9Airflow lower than demandedMedium
EC1Communication error with the outdoor unitHigh
Ed0No shared data on the networkHigh
Ed1Invalid shared dataHigh
Ed4Shared data rejected by the controlHigh
FAnConstant fanLow
FCLFault recall (outdoor communicating units)Low
Flashing optionMenu option flashing = not yet selectedLow
HPCompressor heat, single stageLow
HP1Compressor heat, low stage (comm)Low
HP2Compressor heat, high stage (comm)Low
HtElectric heat, single stageLow
Ht1Electric heat (Ht1)Low
Ht2Electric heat, high stageLow
IdlIdle - no callLow
L6FFault recall (furnace-type menu)Low
LrnRestart indoor-outdoor communicationLow
Rx LED rapid flashGreen receive LED rapid flashing - normal network trafficLow

Troubleshooting the AVPTC49D14

All Goodman Air Handler error codes →

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.