Kinghome Heat Pump Error Codes
80 Kinghome Heat Pump error codes and diagnostic codes, with causes and troubleshooting steps for each. Select a code, or find your model below.
Kinghome Heat Pump error codes list
Find codes by Kinghome model
Kinghome Ultranixx Eco
KD24UHIKD24UHOKD30UHIKD30UHOKD36UHIKD36UHOKD42UHIKD42UHOKD48UHIKD48UHOKD60UHIKD60UHO
Kinghome KM HEDI
Kinghome KM HF1DI
KM09HF1DIKM12HF1DIKM18HF1DIKM21HF1DIKM24HF1DI
Kinghome KM HT1DI
KM09HT1DIKM12HT1DIKM18HT1DIKM24HT1DI
Kinghome Ultranixx
KU24UH2IKU36UH2IKU36UHOKU48UH2IKU60UH2IKU60UHO
Heat Pump troubleshooting guides
- 2 flashes: HPS open ≥6 s; 3: discharge >263°F; 4: discharge <90°F after 1 h; 5: defrost failure; 6: discharge sensor short; 7: outdoor sensor open/short; 9: bonnet sensor fail All brands · Heat Pump
- Auxiliary heat indicator light is on All brands · Heat Pump
- Cleaning the outdoor unit finish All brands · Heat Pump
- Excess ice on outdoor coil All brands · Heat Pump
- Extremely high head pressure in heating (dual fuel) All brands · Heat Pump
- Insufficient heat in cold weather All brands · Heat Pump
- Liquid slugging / compressor damage in heating All brands · Heat Pump
- No mode change / wrong mode All brands · Heat Pump
- Odour at registers (dirty sock) All brands · Heat Pump
- Outdoor coil airflow clearance All brands · Heat Pump
- Poor heating but OK cooling (or vice-versa) All brands · Heat Pump
- Service problem analysis (Amana chart excerpt) All brands · Heat Pump
- Subcooling too high All brands · Heat Pump
- Subcooling too low vs mfr target All brands · Heat Pump
- TXV bulb/diaphragm failure All brands · Heat Pump
- Water-source: coil freezing All brands · Heat Pump
- Won't change mode / both coils same temperature All brands · Heat Pump
- Wrong superheat after line-set change; poor capacity All brands · Heat Pump
- Force a defrost cycle from the remote Kinghome · Heat Pump
- Force a defrost from the outdoor board (debug item 06) Kinghome · Heat Pump
- Force cooling or heating from the outdoor board (debug item 09) Kinghome · Heat Pump
- Open the outdoor board debug menu (SW1 held 5 s) Kinghome · Heat Pump
- Start refrigerant recovery from the outdoor board (debug item 08) Kinghome · Heat Pump
- Start the pilot (test) run from the remote Kinghome · Heat Pump
- Switch between defrosting mode 1 and 2 Kinghome · Heat Pump
Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.