Kinghome Heat Pump Error Codes

Updated · by Aurora Star Tech Inc.

80 Kinghome Heat Pump error codes and diagnostic codes, with causes and troubleshooting steps for each. Select a code, or find your model below.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Kinghome Heat Pump error codes list

CodeMeaningSeverity
+ - + - + -Forced defrost request (remote key sequence)Low
01Forced operation value: coolingLow
02Forced operation value: heatingLow
06Debug menu item 06: forced defrostLow
08Debug menu item 08: refrigerant recoveryLow
8°C8 degC heating mode activeLow
09Debug menu item 09: forced operationLow
88Sleep curve editing (remote)Low
A1Outdoor fan IPM module protectionHigh
ACOutdoor fan startup failureHigh
AEOutdoor fan current detection errorHigh
AJOutdoor fan out-of-stepHigh
C4ODU jumper cap errorMedium
C5Jumper cap missing or wrongMedium
C8ODU drive jumper cap errorMedium
Cool lampCool lamp lit (cooling mode)Low
ddPilot (test) run in progressLow
Dry lampDry lamp lit (dry mode)Low
E1High pressure protection / high-pressure sensor faultHigh
E2Indoor coil anti-freeze protectionMedium
E3Low pressure protection / low-pressure sensor faultHigh
E5Overcurrent protectionMedium
E6Indoor/outdoor communication faultHigh
E8High temperature resistance (overload) protectionMedium
E9Water overflow protectionMedium
EEMemory chip faultHigh
EUFrequency reduced - module too hotLow
F0Refrigerant recovery modeLow
F1Indoor room temperature sensor faultMedium
F2Sensor fault (indoor coil or outdoor condenser)Medium
F3Outdoor ambient temperature sensor faultMedium
F5Outdoor discharge temperature sensor faultMedium
F6Frequency limit for overload / ODU tube sensor faultMedium
F9Frequency reduced - high discharge temperatureLow
FHFrequency reduced - anti-freezeLow
Filter clean iconReminder to clean the air filterLow
Function lock iconWired controller keys lockedLow
H1Defrosting mode 1 selected (remote display)Low
H2Defrosting mode 2 selected (remote display)Low
H3Compressor overload protectionHigh
H4Overload protection (high condensing pressure)High
H5IPM module protectionCritical
H6Fan motor feedback fault (indoor or outdoor)High
H7Compressor out-of-stepHigh
HCPFC protectionHigh
Heat lampHeat lamp lit (heating mode)Low
Heat lamp 10 s on / 0.5 s offDefrosting in heating modeLow
L3Outdoor DC fan motor faultHigh
L9Power limit protectionMedium
LCCompressor start failureHigh
Lock iconRemote keypad lockedLow
LPIndoor and outdoor unit mismatchHigh
OFDebug menu option OFFLow
ONDebug menu option ONLow
Operation lampOperation lamp lit (power connected)Low
P0Compressor minimum-frequency test / driver resetLow
P1Compressor rated-frequency test displayLow
P2Compressor maximum-frequency test displayLow
P3Compressor intermediate-frequency test displayLow
P5Compressor phase overcurrentHigh
P6Main-to-driver communication errorHigh
P7Module temperature sensor circuit faultMedium
P8Power module over-temperatureHigh
PAAC current protectionHigh
PcDrive current detection errorHigh
PHDC bus voltage highHigh
PLDC bus voltage lowHigh
PUCapacitor charging failureHigh
SEEnergy-saving mode activeLow
Shielded iconFunctions shielded by remote monitorLow
SW1Outdoor board debug menu (SW1 held 5 s)Low
Temp display selectIndoor display shows set, room or outdoor temperatureLow
Timer lampTimer lamp lit (timer set)Low
Turbo iconTurbo mode activeLow
U1Compressor phase current detection circuit faultHigh
U3DC bus voltage drop faultMedium
U5Whole-unit current detection faultHigh
U7Four-way valve abnormalHigh
ULOutdoor fan overcurrentHigh
X-FAN iconX-FAN (fan dry-off) activeLow

Find codes by Kinghome model

Kinghome Ultranixx Eco

KD24UHIKD24UHOKD30UHIKD30UHOKD36UHIKD36UHOKD42UHIKD42UHOKD48UHIKD48UHOKD60UHIKD60UHO

Kinghome KM HEDI

KM09HEDIKM12HEDIKM18HEDI

Kinghome KM HF1DI

KM09HF1DIKM12HF1DIKM18HF1DIKM21HF1DIKM24HF1DI

Kinghome KM HT1DI

KM09HT1DIKM12HT1DIKM18HT1DIKM24HT1DI

Kinghome Ultranixx

KU24UH2IKU36UH2IKU36UHOKU48UH2IKU60UH2IKU60UHO

Heat Pump troubleshooting guides

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977