Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Kinghome Error Code P0: Compressor minimum-frequency test / driver reset (Heat Pump)

Updated · by Aurora Star Tech Inc.

Kinghome error code P0 on a heat pump means: Compressor minimum-frequency test / driver reset. It is also called Kinghome diagnostic code P0.

Low severityHeat PumpKinghome KM HT1DI · Kinghome KM HF1DI · Kinghome Ultranixx Eco · Kinghome Ultranixx

Homeowner? What Kinghome code P0 means for you

Usually minor Your heat pump is reporting: Compressor minimum-frequency test / driver reset. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Kinghome error code P0 mean?

On the wall units P0 only shows during the minimum-speed test and is not a fault. On Ultranixx units P0 is a driver-board reset protection that triggers 5 s after power-up.

Applies to: Kinghome KM09HT1DI, KM12HT1DI, KM18HT1DI, KM24HT1DI wall mini-splits; Kinghome KM09HF1DI to KM24HF1DI wall mini-splits (Gree GFH..DA/DB); Kinghome Ultranixx Eco KD24UHO to KD60UHO outdoor units with KD..UHI air handlers; Kinghome Ultranixx cold-climate KU36UHO and KU60UHO outdoor units with KU..UH2I and KD..UHI air handlers

Common causes of Kinghome code P0

  • Test mode (wall units)
  • Drive chip 3.3 V supply dip or interrupted programming lead (Ultranixx)
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Kinghome models that use code P0

Show all 27 models

KD24UHIKD24UHOKD30UHIKD30UHOKD36UHIKD36UHOKD42UHIKD42UHOKD48UHIKD48UHOKD60UHIKD60UHOKM09HF1DIKM09HT1DIKM12HF1DIKM12HT1DIKM18HF1DIKM18HT1DIKM21HF1DIKM24HF1DIKM24HT1DIKU24UH2IKU36UH2IKU36UHOKU48UH2IKU60UH2IKU60UHO

Other Kinghome Heat Pump codes

CodeMeaning
H7Compressor out-of-step
HCPFC protection
L3Outdoor DC fan motor fault
L9Power limit protection
LCCompressor start failure
LPIndoor and outdoor unit mismatch
P1Compressor rated-frequency test display
P2Compressor maximum-frequency test display
P3Compressor intermediate-frequency test display
P5Compressor phase overcurrent
P6Main-to-driver communication error
P7Module temperature sensor circuit fault

All Kinghome Heat Pump error codes →

Kinghome code P0: homeowner questions

What does Kinghome code P0 mean?

Compressor minimum-frequency test / driver reset. On the wall units P0 only shows during the minimum-speed test and is not a fault. On Ultranixx units P0 is a driver-board reset protection that triggers 5 s after power-up.

Is it safe to keep using my heat pump with code P0?

Usually yes. Code P0 is normally minor, but if it keeps coming back have it checked.

Can I reset Kinghome code P0 myself?

You can try one reset (power off for 30 seconds, then on). If Kinghome code P0 comes back, the cause is still there and a licensed technician should check it.

Who can fix Kinghome code P0 near me?

Aurora Star Tech Inc. repairs Kinghome heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Source: Kinghome KM09-12-18-24HT1DI service manual, sec. 9.1 error code list; Kinghome KM09-24HF1DI service manual, sec. 11.1 error code list; Kinghome Ultranixx Eco KD24-60UHO service manual, sec. 3.3-3.4; Kinghome Ultranixx cold-climate KU36/60UHO service manual GC202306, sec. 3.3-3.4. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service