Kinghome Error Code U7: Four-way valve abnormal (Heat Pump)

Updated · by Aurora Star Tech Inc.

Kinghome error code U7 on a heat pump means: Four-way valve abnormal. It is also called Kinghome diagnostic code U7.

High severityHeat PumpKinghome KM HT1DI · Kinghome KM HF1DI

Homeowner? What Kinghome code U7 means for you

Call a technician Your heat pump is reporting: Four-way valve abnormal. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Kinghome error code U7 mean?

The reversing valve did not work correctly; heating stops.

Applies to: Kinghome KM09HT1DI, KM12HT1DI, KM18HT1DI, KM24HT1DI wall mini-splits; Kinghome KM09HF1DI to KM24HF1DI wall mini-splits (Gree GFH..DA/DB)

Common causes of Kinghome code U7

  • Supply below 175 VAC
  • 4V terminal loose or broken
  • Failed reversing valve coil
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Kinghome models that use code U7

KM09HF1DIKM09HT1DIKM12HF1DIKM12HT1DIKM18HF1DIKM18HT1DIKM21HF1DIKM24HF1DIKM24HT1DI

Other Kinghome Heat Pump codes

CodeMeaning
Temp display selectIndoor display shows set, room or outdoor temperature
Timer lampTimer lamp lit (timer set)
Turbo iconTurbo mode active
U1Compressor phase current detection circuit fault
U3DC bus voltage drop fault
U5Whole-unit current detection fault
ULOutdoor fan overcurrent
X-FAN iconX-FAN (fan dry-off) active

All Kinghome Heat Pump error codes →

Kinghome code U7: homeowner questions

What does Kinghome code U7 mean?

Four-way valve abnormal. The reversing valve did not work correctly; heating stops.

Is it safe to keep using my heat pump with code U7?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Kinghome code U7 myself?

You can try one reset (power off for 30 seconds, then on). If Kinghome code U7 comes back, the cause is still there and a licensed technician should check it.

Who can fix Kinghome code U7 near me?

Aurora Star Tech Inc. repairs Kinghome heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Kinghome KM09-12-18-24HT1DI service manual, sec. 9.1 error code list; Kinghome KM09-24HF1DI service manual, sec. 11.1 error code list. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977