Kinghome error code ON on a heat pump means: Debug menu option ON. It is also called Kinghome diagnostic code ON.

Low severityHeat PumpKinghome Ultranixx

Homeowner? What Kinghome code ON means for you

Usually minor Your heat pump is reporting: Debug menu option ON. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Kinghome error code ON mean?

ON in the KU outdoor debug menu means the selected function (forced defrost 06 or refrigerant recovery 08) is switched on.

Applies to: Kinghome Ultranixx cold-climate KU36UHO and KU60UHO outdoor units with KU..UH2I and KD..UHI air handlers

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Kinghome models that use code ON

KU24UH2IKU36UH2IKU36UHOKU48UH2IKU60UH2IKU60UHO

Other Kinghome Heat Pump codes

CodeMeaning
L3Outdoor DC fan motor fault
L9Power limit protection
LCCompressor start failure
Lock iconRemote keypad locked
LPIndoor and outdoor unit mismatch
OFDebug menu option OFF
Operation lampOperation lamp lit (power connected)
P0Compressor minimum-frequency test / driver reset
P1Compressor rated-frequency test display
P2Compressor maximum-frequency test display
P3Compressor intermediate-frequency test display
P5Compressor phase overcurrent

All Kinghome Heat Pump error codes →

Kinghome code ON: homeowner questions

What does Kinghome code ON mean?

Debug menu option ON. ON in the KU outdoor debug menu means the selected function (forced defrost 06 or refrigerant recovery 08) is switched on.

Is it safe to keep using my heat pump with code ON?

Usually yes. Code ON is normally minor, but if it keeps coming back have it checked.

Can I reset Kinghome code ON myself?

You can try one reset (power off for 30 seconds, then on). If Kinghome code ON comes back, the cause is still there and a licensed technician should check it.

Who can fix Kinghome code ON near me?

Aurora Star Tech Inc. repairs Kinghome heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Kinghome Ultranixx cold-climate KU36/60UHO service manual GC202306, sec. 2.3.5 and 2.3.6. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.