Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Kinghome Error Code FH: Frequency reduced – anti-freeze (Heat Pump)

Updated · by Aurora Star Tech Inc.

Kinghome error code FH on a heat pump means: Frequency reduced - anti-freeze. It is also called Kinghome diagnostic code FH.

Low severityHeat PumpKinghome KM HT1DI · Kinghome KM HF1DI

Homeowner? What Kinghome code FH means for you

Usually minor Your heat pump is reporting: Frequency reduced - anti-freeze. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Kinghome error code FH mean?

Compressor speed is limited to prevent coil icing.

Applies to: Kinghome KM09HT1DI, KM12HT1DI, KM18HT1DI, KM24HT1DI wall mini-splits; Kinghome KM09HF1DI to KM24HF1DI wall mini-splits (Gree GFH..DA/DB)

Common causes of Kinghome code FH

  • Poor indoor return air
  • Low indoor fan speed
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Kinghome models that use code FH

KM09HF1DIKM09HT1DIKM12HF1DIKM12HT1DIKM18HF1DIKM18HT1DIKM21HF1DIKM24HF1DIKM24HT1DI

Other Kinghome Heat Pump codes

CodeMeaning
F3Outdoor ambient temperature sensor fault
F4Sensor fault (outdoor condenser or discharge)
F5Outdoor discharge temperature sensor fault
F6Frequency limit for overload / ODU tube sensor fault
F8Frequency reduced - overcurrent
F9Frequency reduced - high discharge temperature
H3Compressor overload protection
H4Overload protection (high condensing pressure)
H5IPM module protection
H6Fan motor feedback fault (indoor or outdoor)
H7Compressor out-of-step
HCPFC protection

All Kinghome Heat Pump error codes →

Kinghome code FH: homeowner questions

What does Kinghome code FH mean?

Frequency reduced - anti-freeze. Compressor speed is limited to prevent coil icing.

Is it safe to keep using my heat pump with code FH?

Usually yes. Code FH is normally minor, but if it keeps coming back have it checked.

Can I reset Kinghome code FH myself?

You can try one reset (power off for 30 seconds, then on). If Kinghome code FH comes back, the cause is still there and a licensed technician should check it.

Who can fix Kinghome code FH near me?

Aurora Star Tech Inc. repairs Kinghome heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Source: Kinghome KM09-12-18-24HT1DI service manual, sec. 9.1 error code list; Kinghome KM09-24HF1DI service manual, sec. 11.1 error code list. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.