Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Kinghome Error Code Heat lamp 10 s on / 0.5 s off: Defrosting in heating mode (Heat Pump)

Updated · by Aurora Star Tech Inc.

Kinghome error code Heat lamp 10 s on / 0.5 s off on a heat pump means: Defrosting in heating mode. It is also called Kinghome diagnostic code Heat lamp 10 s on / 0.5 s off.

Low severityHeat PumpKinghome KM HT1DI · Kinghome KM HF1DI

Homeowner? What Kinghome code Heat lamp 10 s on / 0.5 s off means for you

Usually minor Your heat pump is reporting: Defrosting in heating mode. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Kinghome error code Heat lamp 10 s on / 0.5 s off mean?

During defrosting in heating mode the heating lamp pattern is off for about 3 s then blinks once, with the lamp on for 10 s and off for 0.5 s. The compressor keeps running while the indoor fan stops. The manual calls this the normal state. The on-screen code for this row did not survive the text export, so only the lamp pattern is given.

Applies to: Kinghome KM09HT1DI, KM12HT1DI, KM18HT1DI, KM24HT1DI wall mini-splits; Kinghome KM09HF1DI to KM24HF1DI wall mini-splits (Gree GFH..DA/DB)

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Kinghome models that use code Heat lamp 10 s on / 0.5 s off

KM09HF1DIKM09HT1DIKM12HF1DIKM12HT1DIKM18HF1DIKM18HT1DIKM21HF1DIKM24HF1DIKM24HT1DI

Other Kinghome Heat Pump codes

CodeMeaning
H4Overload protection (high condensing pressure)
H5IPM module protection
H6Fan motor feedback fault (indoor or outdoor)
H7Compressor out-of-step
HCPFC protection
Heat lampHeat lamp lit (heating mode)
L3Outdoor DC fan motor fault
L9Power limit protection
LCCompressor start failure
Lock iconRemote keypad locked
LPIndoor and outdoor unit mismatch
OFDebug menu option OFF

All Kinghome Heat Pump error codes →

Kinghome code Heat lamp 10 s on / 0.5 s off: homeowner questions

What does Kinghome code Heat lamp 10 s on / 0.5 s off mean?

Defrosting in heating mode. During defrosting in heating mode the heating lamp pattern is off for about 3 s then blinks once, with the lamp on for 10 s and off for 0.5 s. The compressor keeps running while the indoor fan stops. The manual calls this the normal…

Is it safe to keep using my heat pump with code Heat lamp 10 s on / 0.5 s off?

Usually yes. Code Heat lamp 10 s on / 0.5 s off is normally minor, but if it keeps coming back have it checked.

Can I reset Kinghome code Heat lamp 10 s on / 0.5 s off myself?

You can try one reset (power off for 30 seconds, then on). If Kinghome code Heat lamp 10 s on / 0.5 s off comes back, the cause is still there and a licensed technician should check it.

Who can fix Kinghome code Heat lamp 10 s on / 0.5 s off near me?

Aurora Star Tech Inc. repairs Kinghome heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Kinghome KM09-12-18-24HT1DI service manual, sec. 9.1 indicator table (Defrosting row); sec. 6.2 (8); Kinghome KM09-24HF1DI service manual, sec. 11.1 indicator table (Defrosting row). Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service