Kinghome KM09HT1DI error codes list

CodeMeaningSeverity
C5Jumper cap missing or wrongMedium
E1High pressure protection / high-pressure sensor faultHigh
E2Indoor coil anti-freeze protectionMedium
E3Low pressure protection / low-pressure sensor faultHigh
E4Compressor discharge temperature too highHigh
E5Overcurrent protectionMedium
E6Indoor/outdoor communication faultHigh
E8High temperature resistance (overload) protectionMedium
E9Water overflow protectionMedium
EEMemory chip faultHigh
EUFrequency reduced - module too hotLow
F0Refrigerant recovery modeLow
F1Indoor room temperature sensor faultMedium
F2Sensor fault (indoor coil or outdoor condenser)Medium
F3Outdoor ambient temperature sensor faultMedium
F4Sensor fault (outdoor condenser or discharge)Medium
F5Outdoor discharge temperature sensor faultMedium
F6Frequency limit for overload / ODU tube sensor faultMedium
F8Frequency reduced - overcurrentLow
F9Frequency reduced - high discharge temperatureLow
FHFrequency reduced - anti-freezeLow
H3Compressor overload protectionHigh
H5IPM module protectionCritical
H6Fan motor feedback fault (indoor or outdoor)High
H7Compressor out-of-stepHigh
HCPFC protectionHigh
L3Outdoor DC fan motor faultHigh
L9Power limit protectionMedium
LCCompressor start failureHigh
LPIndoor and outdoor unit mismatchHigh
P0Compressor minimum-frequency test / driver resetLow
P1Compressor rated-frequency test displayLow
P2Compressor maximum-frequency test displayLow
P3Compressor intermediate-frequency test displayLow
P5Compressor phase overcurrentHigh
P7Module temperature sensor circuit faultMedium
P8Power module over-temperatureHigh
PHDC bus voltage highHigh
PLDC bus voltage lowHigh
PUCapacitor charging failureHigh
U1Compressor phase current detection circuit faultHigh
U3DC bus voltage drop faultMedium
U5Whole-unit current detection faultHigh
U7Four-way valve abnormalHigh

All Kinghome Heat Pump error codes →

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.