Gree GMV-V36WL/C-T(U) Error Codes

Updated · by Aurora Star Tech Inc.

Gree GMV-V36WL/C-T(U) error codes and diagnostic codes (also listed as GMV-V36WL/C-T, GMV-36WL/C-T(U)). The GMV-V36WL/C-T(U) is a Gree heat pump in the Gree GMV6 Mini VRF series.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Gree GMV-V36WL/C-T(U) error codes list

CodeMeaningSeverity
0CDefaults restored (reset in progress)Low
03/01Commissioning step 03: confirming outdoor unit quantityLow
04/00-16Commissioning step 04: indoor unit quantityLow
06Commissioning step 06: checking outdoor componentsLow
07Commissioning step 07: checking indoor componentsLow
A0Waiting for commissioning (status)Low
A2Pump-down (refrigerant recycle) modeLow
A3DefrostingLow
A4Oil returnLow
A6Cooling/heating mode of the whole system (menu)Low
A7Outdoor silence mode (menu)Low
A8Vacuum mode (menu)Low
A9Set back functionLow
AbEmergency stopMedium
ACCooling (system status)Low
AdCommissioning step 02: allocating addressesLow
AEAdd refrigerant manually (commissioning)Low
AFFan mode (system status)Low
AHHeating (system status)Low
AJFilter cleaning reminderLow
APCommissioning confirmation (step 12)Low
AURemote emergency stopLow
AyShielding status (remote limit)Low
b1Outdoor ambient sensor open or shorted (15K)Medium
b2Defrost (coil) sensor open or shorted (20K)Medium
b4Sub-cooler liquid outlet sensor open or shorted (20K)Medium
b6Accumulator inlet sensor open or shorted (20K)Medium
bdSub-cooler gas inlet sensor open or shorted (20K)Medium
bHSystem clock abnormalLow
bJHigh and low pressure sensors swappedMedium
C0Communication fault IDU/ODU/wired controllerHigh
C1Main board to DC-DC controller communication faultHigh
C2Main board to compressor drive communication faultHigh
C3Main board to fan drive communication faultHigh
C4Missing indoor unitsHigh
CHIndoor capacity too highMedium
CLIndoor capacity too lowMedium
CPMore than one master wired controllerLow
d1Indoor main board faultHigh
d3Indoor return air sensor open or shorted (15K)Medium
d4Indoor coil inlet pipe sensor open or shorted (20K)Medium
d5Indoor coil middle pipe sensor open or shorted (20K)Medium
d6Indoor coil outlet pipe sensor open or shorted (20K)Medium
d9Indoor jumper cap faultMedium
dbIndoor unit in debugging statusLow
dCIndoor capacity DIP setting wrongMedium
Debug 01-17Outdoor commissioning sequence (steps 01 to 17)Low
dHWired controller board faultLow
dLIndoor discharge air sensor open or shorted (15K)Medium
E0Outdoor unit fault (shown with another code)Medium
E1High pressure protectionHigh
E3Low pressure protectionHigh
E4Compressor discharge temperature too highHigh
EdDrive IPM low temperature protectionMedium
F5Compressor discharge sensor open or shortedMedium
FPOutdoor DC fan motor faultHigh
H8Fan drive module overheatedHigh
H9Inverter fan lost synchronismHigh
HAFan drive memory chip faultHigh
HEInverter fan phase lossHigh
HFFan drive charging circuit faultHigh
HHFan drive DC bus voltage too highHigh
HJInverter fan failed to startHigh
HLFan drive DC bus voltage too lowHigh
HPInverter fan AC current protectionHigh
HUFan drive AC input voltage faultHigh
J1Compressor overcurrentHigh
J74-way valve gas mixingHigh
J8High pressure ratio protectionMedium
J9Low pressure ratio protectionMedium
JAAbnormal pressure protectionHigh
JLHigh pressure too lowHigh
L0Indoor unit faultMedium
L1Indoor fan protectionHigh
L4Wired controller power faultLow
L5Indoor freeze protectionLow
L6Mode conflict (24 V adapter systems)Low
L7No master indoor unitMedium
L8Indoor power insufficientMedium
LAGroup control: indoor series mismatchLow
LbGroup control: units from different systemsLow
LJIndoor function DIP setting wrongMedium
LUPG fan motor zero-crossing faultMedium
n0Auto energy saving (menu)Low
n1Defrost cycle K1 settingLow
n3Forced defrost (menu)Low
n4Maximum output limit (forced energy saving)Low
n5Indoor engineering number offsetLow
n6Fault history queryLow
n7Running parameter queryLow
n8Indoor engineering number queryLow
n9Online indoor unit countLow
nASystem mode: cooling and heatingLow
nbOutdoor and controller barcode queryLow
nCSystem mode: cooling onlyLow
nENegative number prefixLow
nFSystem mode: fan onlyLow
nHSystem mode: heating onlyLow
nJHigh temperature prevention when heating (factory function)Low
nnConnection pipe length modification (factory function)Low
nUCancel indoor long-distance shielding (factory function)Low
oCCommissioning step passed (OK)Low
oFDebugging finished / standbyLow
onValve test running / unit startedLow
P4Compressor drive PFC protectionHigh
P6Compressor drive IPM protectionHigh
P7Inverter module temperature sensor faultMedium
P8Inverter module overheatedHigh
P9Inverter compressor lost synchronismHigh
PACompressor drive memory chip faultHigh
PCCompressor drive current sensing faultHigh
PEInverter compressor phase lossHigh
PFCompressor drive charging circuit faultHigh
PHDC bus voltage too highHigh
PJInverter compressor failed to startHigh
PLDC bus voltage too lowHigh
Power LEDMain board and drive board power LEDs onLow
PPInverter compressor AC current protectionHigh
U0Compressor preheat not finishedLow
U2Outdoor capacity code / jumper wrongMedium
U4Refrigerant shortage at startupHigh
U6Service valves not openedMedium
UCMaster indoor unit set successfullyLow
UERefrigerant charging invalidMedium

Troubleshooting the GMV-V36WL/C-T(U)

All Gree Heat Pump error codes →

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.