Updated · by Aurora Star Tech Inc.

Noise or vibration - Gree ductless on a Gree heat pump: Clicks, gurgles or rattles from the indoor or outdoor unit. Gree Sapphire, Livo, Vireo and Multi21+. Many of the noises are normal and customers just have not heard them before. Sort normal from abnormal first.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Gree Sapphire 9-24k (SAP..HP230V1A), Livo GEN4 30-36k (4LIV..HP230V1A), Vireo GEN3 9-24k (3VIR..HP115/230V1A), Multi21+ 18-24k multi-zone (MULTI..HP230V1CO)

Common causes of noise or vibration - gree ductless

  • Plastic expanding at start and stop (normal)
  • Refrigerant flow noise (normal)
  • Loose parts or debris
  • 4-way valve coil buzz
  • Compressor not sitting on its mounts, or internal noise and overcharge

How to fix noise or vibration - gree ductless: step by step

  1. Cracking or water-flow sounds at start and stop are normal and fade in a few minutes, tell the customer
  2. Remove debris, tighten screws and add damping where parts touch
  3. Replace a buzzing 4-way valve coil
  4. Check compressor feet and bolts, because a compressor off its mounts transmits vibration to the cabinet
  5. If noise is internal, check for overcharge, else replace the compressor
  6. Power off before opening panels, and use a licensed tech for refrigerant work
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Gree Heat Pump codes

Models

Gree Vireo GEN3

3VIR09HP115V1A3VIR09HP230V1A3VIR12HP115V1A3VIR12HP230V1A3VIR18HP230V1A3VIR24HP230V1A

Gree Livo GEN4

4LIV30HP230V1AH4LIV36HP230V1AH

Gree GMV6 Mini VRF

GMV-V36WL/C-T(U)GMV-V48WL/C-T(U)GMV-V60WL/C-T(U)

Gree Multi21+

MULTI18HP230V1COMULTI24HP230V1CO

Gree Sapphire

SAP09HP230V1AHSAP12HP230V1AHSAP18HP230V1AHSAP24HP230V1AH

Source: Gree Sapphire 9-12k (SAP09-12HP230V1A) service.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Sapphire 18-24k (SAP18-24HP230V1A) service.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Livo GEN4 30-36k (4LIV30-36HP230V1A) service.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Vireo GEN3 9-24k (3VIR..HP115-230V1A) service GREE_VIREOGEN3_SERVICE_090921.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Multi21+ multi-zone 18-24k (MULTI18-24HP230V1CO) service.pdf - section 9.3 Maintenance Method for Normal Malfunction. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977