Gree Heat Pump: Weak cooling or heating – Gree ductless
Weak cooling or heating - Gree ductless on a Gree heat pump: The mini split runs but the room never gets to temperature. Gree Sapphire, Livo, Vireo and Multi21+. Most of this comes from the simple end of the list, then installation, then refrigerant.
Applies to: Gree Sapphire 9-24k (SAP..HP230V1A), Livo GEN4 30-36k (4LIV..HP230V1A), Vireo GEN3 9-24k (3VIR..HP115/230V1A), Multi21+ 18-24k multi-zone (MULTI..HP230V1CO)
Common causes of weak cooling or heating - gree ductless
- Setpoint or fan speed too low
- Dirty filter
- Poor indoor or outdoor unit location
- Refrigerant leak
- 4-way valve fault, giving cold air in heating
- Capillary or EEV restriction
- Service valve not fully open
How to fix weak cooling or heating - gree ductless: step by step
- Check setpoint and set fan to high or medium, because low fan speed cuts delivered capacity
- Clean the filter, a clogged filter chokes airflow
- Check installation clearances and shading of the outdoor unit, blocked air starves the coil
- Compare supply air temperature and pressures with normal, low readings point to a leak or restriction
- Open both service valves fully, a half-open valve acts like a restriction
- Cold air in heating with good charge: replace the 4-way valve
- Refrigerant work needs a licensed technician
If the unit shows an error code, look it up: Gree Heat Pump codes
Models
Gree Vireo GEN3
3VIR09HP115V1A3VIR09HP230V1A3VIR12HP115V1A3VIR12HP230V1A3VIR18HP230V1A3VIR24HP230V1A
Gree Livo GEN4
4LIV30HP230V1AH4LIV36HP230V1AH
Gree GMV6 Mini VRF
GMV-V36WL/C-T(U)GMV-V48WL/C-T(U)GMV-V60WL/C-T(U)
Gree Multi21+
MULTI18HP230V1COMULTI24HP230V1CO
Gree Sapphire
SAP09HP230V1AHSAP12HP230V1AHSAP18HP230V1AHSAP24HP230V1AH
Source: Gree Sapphire 9-12k (SAP09-12HP230V1A) service.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Sapphire 18-24k (SAP18-24HP230V1A) service.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Livo GEN4 30-36k (4LIV30-36HP230V1A) service.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Vireo GEN3 9-24k (3VIR..HP115-230V1A) service GREE_VIREOGEN3_SERVICE_090921.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Multi21+ multi-zone 18-24k (MULTI18-24HP230V1CO) service.pdf - section 9.3 Maintenance Method for Normal Malfunction. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.