Gree Error Code LJ: Indoor function DIP setting wrong (Heat Pump)

Updated · by Aurora Star Tech Inc.

Gree error code LJ on a heat pump means: Indoor function DIP setting wrong. It is also called Gree diagnostic code LJ.

Medium severityHeat PumpGree GMV6 Mini VRF

Homeowner? What Gree code LJ means for you

Check, then call Your heat pump is reporting: Indoor function DIP setting wrong. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Gree error code LJ mean?

Function DIP switches are wrong, usually after a board replacement.

Applies to: Gree GMV6 Ultra Heat Mini VRF 36-60k (GMV-V..WL/C-T(U))

Common causes of Gree code LJ

  • DIP switches not copied from old board
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Gree models that use code LJ

GMV-V36WL/C-T(U)GMV-V48WL/C-T(U)GMV-V60WL/C-T(U)

Other Gree Heat Pump codes

CodeMeaning
L8Indoor power insufficient
L9Power protection
LAGroup control: indoor series mismatch
LbGroup control: units from different systems
LCCompressor failed to start
LdCompressor phase loss
LPIndoor and outdoor units do not match
LUPG fan motor zero-crossing fault
oEUndefined outdoor unit error
P4Compressor drive PFC protection
P5Compressor phase overcurrent
P6Compressor drive IPM protection

All Gree Heat Pump error codes →

Gree code LJ: homeowner questions

What does Gree code LJ mean?

Indoor function DIP setting wrong. Function DIP switches are wrong, usually after a board replacement.

Is it safe to keep using my heat pump with code LJ?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Gree code LJ myself?

You can try one reset (power off for 30 seconds, then on). If Gree code LJ comes back, the cause is still there and a licensed technician should check it.

Who can fix Gree code LJ near me?

Aurora Star Tech Inc. repairs Gree heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Gree GMV6 Ultra Heat Mini VRF 36-60k (GMV-V36-48-60WL-C-T(U)) service.pdf - section Chapter 3 Faults, 4.1 Error Indication. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.