Gree Error Code d1: Indoor main board fault (Heat Pump)

Updated · by Aurora Star Tech Inc.

Gree error code d1 on a heat pump means: Indoor main board fault. It is also called Gree diagnostic code d1.

High severityHeat PumpGree GMV6 Mini VRF

Homeowner? What Gree code d1 means for you

Call a technician Your heat pump is reporting: Indoor main board fault. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Gree error code d1 mean?

Chip fault on the indoor board.

Applies to: Gree GMV6 Ultra Heat Mini VRF 36-60k (GMV-V..WL/C-T(U))

Common causes of Gree code d1

  • Indoor board failed
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Gree models that use code d1

GMV-V36WL/C-T(U)GMV-V48WL/C-T(U)GMV-V60WL/C-T(U)

Other Gree Heat Pump codes

CodeMeaning
C3Main board to fan drive communication fault
C4Missing indoor units
C5Jumper (capacity) cap missing or bad
CHIndoor capacity too high
CLIndoor capacity too low
CPMore than one master wired controller
d3Indoor return air sensor open or shorted (15K)
d4Indoor coil inlet pipe sensor open or shorted (20K)
d5Indoor coil middle pipe sensor open or shorted (20K)
d6Indoor coil outlet pipe sensor open or shorted (20K)
d9Indoor jumper cap fault
dCIndoor capacity DIP setting wrong

All Gree Heat Pump error codes →

Gree code d1: homeowner questions

What does Gree code d1 mean?

Indoor main board fault. Chip fault on the indoor board.

Is it safe to keep using my heat pump with code d1?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Gree code d1 myself?

You can try one reset (power off for 30 seconds, then on). If Gree code d1 comes back, the cause is still there and a licensed technician should check it.

Who can fix Gree code d1 near me?

Aurora Star Tech Inc. repairs Gree heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Gree GMV6 Ultra Heat Mini VRF 36-60k (GMV-V36-48-60WL-C-T(U)) service.pdf - section Chapter 3 Faults, 4.1 Error Indication. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977