Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Gree Error Code P9: Inverter compressor lost synchronism (Heat Pump)

Updated · by Aurora Star Tech Inc.

Gree error code P9 on a heat pump means: Inverter compressor lost synchronism. It is also called Gree diagnostic code P9.

High severityHeat PumpGree GMV6 Mini VRF

Homeowner? What Gree code P9 means for you

Call a technician Your heat pump is reporting: Inverter compressor lost synchronism. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Gree error code P9 mean?

Compressor drive fault: inverter compressor lost synchronism.

Applies to: Gree GMV6 Ultra Heat Mini VRF 36-60k (GMV-V..WL/C-T(U))

Common causes of Gree code P9

  • Compressor winding fault
  • Poor refrigerant flow or dirty coils/filters
  • Supply voltage problem

A technician checks these and 1 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Gree models that use code P9

GMV-V36WL/C-T(U)GMV-V48WL/C-T(U)GMV-V60WL/C-T(U)

Other Gree Heat Pump codes

CodeMeaning
P2Compressor maximum-frequency test display
P3Compressor intermediate-frequency test display
P4Compressor drive PFC protection
P6Compressor drive IPM protection
P7Inverter module temperature sensor fault
P8Inverter module overheated
PACompressor drive memory chip fault
PCCompressor drive current sensing fault
PEInverter compressor phase loss
PFCompressor drive charging circuit fault
PHDC bus voltage too high
PJInverter compressor failed to start

All Gree Heat Pump error codes →

Gree code P9: homeowner questions

What does Gree code P9 mean?

Inverter compressor lost synchronism. Compressor drive fault: inverter compressor lost synchronism.

Is it safe to keep using my heat pump with code P9?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Gree code P9 myself?

You can try one reset (power off for 30 seconds, then on). If Gree code P9 comes back, the cause is still there and a licensed technician should check it.

Who can fix Gree code P9 near me?

Aurora Star Tech Inc. repairs Gree heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Gree GMV6 Ultra Heat Mini VRF 36-60k (GMV-V36-48-60WL-C-T(U)) service.pdf - section Chapter 3 Faults, 4.1 Error Indication. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service