Viessmann 020028 Error Codes

Updated · by Aurora Star Tech Inc.

Viessmann 020028 error codes and diagnostic codes. The 020028 is a Viessmann heat pump in the Vitocal 100-AW series.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Viessmann 020028 error codes list

CodeMeaningSeverity
Circuit Config. ErrorHeating circuit configuration errorLow
CommunicationIndoor to outdoor unit communication errorMedium
Cooling temp.Cold buffer temperature sensor errorMedium
Curves Config. ErrorHeating curve configuration errorLow
DHW Tank Temp.DHW tank temperature sensor errorMedium
E10ReservedLow
E11ReservedLow
E12Heating return temperature sensor failureMedium
E13Heating outlet water temperature sensor failureMedium
E14High pressure protectionHigh
E15ReservedLow
E16Low pressure protectionHigh
E17ReservedLow
E18Water flow protectionMedium
E19Electric heating overload protectionHigh
E20Exhaust temperature overprotectionHigh
E23Fan 1 overload speed limitMedium
E24Fan 2 overload speed limitMedium
E25Inlet/outlet water temperature difference exceededMedium
E26Outlet water over heatHigh
E27Mixing outlet water temperature sensor failureMedium
E28Hot water return temp sensor failureMedium
E29Hot water outlet water temp sensor failureMedium
E34High pressure protection, 3 timesCritical
E36Low pressure protection, 3 timesCritical
E38Water flow protection, 3 timesCritical
E39Electric heating protection, 3 timesCritical
E40Discharge over heat protection, 3 timesCritical
E42Inlet/outlet water temp difference exceeded, 3 timesCritical
E43Outlet water temp too low, 3 timesCritical
E44Outlet water over temperature protection, 3 timesCritical
E50Inlet water temp failureMedium
E51Outlet water temp failureMedium
E52Coil temp failureMedium
E53Ambient temp failureMedium
E54Suction temp failureMedium
E55Anti-freeze temp failureMedium
E56Coil outlet water temp sensor failureMedium
E59EVI inlet temp failureMedium
E68Hot water temp failureMedium
E110Primary anti-freeze protectionLow
E111Secondary anti-freeze protectionLow
E112Anti-freeze protectionMedium
E114Room temp failureMedium
E312Anti-freeze protection, 3 timesCritical
E510EVI outlet temp failureMedium
E511Discharge temp failureMedium
E513System 1 pressure sensor failureMedium
E514Low ambient temp failureMedium
E515Outlet temp too low protectionMedium
E611Fan 1 failureHigh
E612Fan 2 failureHigh
E613Communication failure (main board with fan motor module board)High
Heat Pump ModuleHeat pump error (outdoor unit)High
HP Inlet Temp.Outdoor unit inlet temperature sensor errorMedium
HP Low PressureOutdoor unit low refrigerant pressureHigh
HP Outlet Temp.Outdoor unit outlet temperature sensor errorMedium
IDU PumpIndoor unit circulation pump errorMedium
Inlet Temp.Return temperature sensor errorMedium
Low BatteryLow batteryLow
Low PressureLow heating medium pressureHigh
Outlet Temp.Outlet temperature sensor errorMedium
Outside Temp.Outside temperature sensor errorMedium
Press. SensorSystem pressure sensor error (indoor unit)Medium
Room Temp.Room temperature sensor errorMedium
Temp. HC1Circuit 1 temperature sensor errorMedium
Temp. HC2Circuit 2 temperature sensor errorMedium
Thermal Cut-offFixed high limit tripped (indoor unit)High

Troubleshooting the 020028

All Viessmann Heat Pump error codes →

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.