Weil-McLain ECO HP 55 error codes and diagnostic codes (also listed as ECO HP 55 MBH, ECO-HP 55). The ECO HP 55 is a Weil-McLain heat pump in the Weil-McLain ECO HP series.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Weil-McLain ECO HP 55 error codes list

CodeMeaningSeverity
bHPED board faultHigh
C7Inverter heat sink too hotHigh
CLWater pump communication wire faultMedium
E0Water flow fault (E8 three times)Critical
E2Communication fault between wired controller and indoor unitMedium
E5Outdoor coil temperature sensor (T3) faultMedium
E6Outdoor air temperature sensor (T4) faultMedium
E7Buffer tank temperature sensor (Tbt1) faultMedium
E8Water flow faultHigh
E9Compressor suction temperature sensor (Th) faultMedium
EACompressor discharge temperature sensor (Tp) faultMedium
EbSolar panel temperature sensor (Tsolar) faultMedium
EdWater inlet temperature sensor (Tw_in) faultMedium
EEHydro-box PCB EEPROM faultMedium
ELCommunication fault between hydraulic module and MH-kitMedium
F1DC bus low voltageHigh
H0Communication fault between indoor and outdoor unitHigh
H1Communication fault between main board and inverter board (outdoor)High
H2Refrigerant temperature sensor at plate HX outlet (heating) (T2) faultMedium
H3Refrigerant temperature sensor at plate HX inlet (heating) (T2B) faultMedium
H4L0/L1 protection happened 3 times in an hourHigh
H5Room temperature sensor (Ta) faultLow
H6DC fan motor faultHigh
H7AC supply voltage protectionMedium
H8Pressure sensor faultMedium
H9Zone 2 water temperature sensor (Tw2) faultMedium
HAWater outlet temperature sensor (Tw_out) faultMedium
HbPP three times and Tw_out under 44.6 FCritical
HECommunication fault with Ta / room thermostat transfer boardLow
HFOutdoor unit EEPROM faultMedium
HHH6 fan fault 10 times in 120 minutesHigh
HPLow pressure in cooling, 3 times in an hourHigh
L0DC compressor inverter module faultHigh
L1DC bus low voltage protectionHigh
L2DC bus high voltage protectionHigh
L4MCE faultHigh
L5Zero speed protectionHigh
L7Phase loss protectionHigh
L8Compressor speed changed more than 15 Hz in one secondHigh
L9Compressor speed off target by more than 15 HzHigh
P0Low pressure protectionHigh
P1High pressure protectionHigh
P3AC current protectionHigh
P4Compressor discharge temperature too highHigh
P5Water temperature difference too high (Tw_out - Tw_in)High
P6Inverter module protectionHigh
PbAnti-freeze modeLow
PdOutdoor coil (T3) temperature too highHigh
PPTw_out - Tw_in reading not normalMedium

Troubleshooting the ECO HP 55

All Weil-McLain Heat Pump error codes →

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.