Viessmann WB1B Error Codes
Viessmann WB1B error codes and diagnostic codes. The WB1B is a Viessmann boiler in the Vitodens 100-W series.
Viessmann WB1B error codes list
| Code | Meaning | Severity |
|---|---|---|
| a9 | Communication fault with OpenTherm device | Low |
| F.359 | No ignition spark | High |
Troubleshooting the WB1B
- Condensing/corrosion of conventional boiler All brands · Boiler
- No heat or some zones cold All brands · Boiler
- Noise All brands · Boiler
- Poor heat / circulation All brands · Boiler
- Relief valve weeps every cycle / pressure climbs All brands · Boiler
- Short cycling / wasted fuel All brands · Boiler
- Symptoms of air in system All brands · Boiler
- Uneven heating All brands · Boiler
- Won't fire All brands · Boiler
- Acknowledged fault comes back Viessmann · Boiler
- Actuator test on the boiler group Viessmann · Boiler
- Adjusting room temperature with an external thermostat Viessmann · Boiler
- Antifreeze in heating system Viessmann · Boiler
- Boiler will not reset after F2 fault shutdown Viessmann · Boiler
- Burner lock-out after failed ignition Viessmann · Boiler
- Burner shuts off below set-point and restarts repeatedly (cycling) Viessmann · Boiler
- Calling up system configuration parameters Viessmann · Boiler
- Check control unit fuse F4 Viessmann · Boiler
- Check flue gas temperature sensor and fixed high limit Viessmann · Boiler
- Check or replace the plate type heat exchanger (CombiPLUS) Viessmann · Boiler
- Check outlet temperature sensor (CombiPLUS) Viessmann · Boiler
- Check power pump module fuse F1 Viessmann · Boiler
- Checking active maintenance messages Viessmann · Boiler
- Checking combustion quality (CO2 or O2 and CO) Viessmann · Boiler
- Checking gas equipment for leaks at operating pressure Viessmann · Boiler
- Checking safety valve, low water cut-offs and pumps Viessmann · Boiler
- Checking the DHW flow limiter and filter (gas condensing combi) Viessmann · Boiler
- Checking the expansion tank and system pressure Viessmann · Boiler
- Checks before commissioning the flue gas connection Viessmann · Boiler
- Choosing the boiler location and room conditions Viessmann · Boiler
- Clocking the natural gas meter to verify burner input Viessmann · Boiler
- Combustion air cover and room air operation Viessmann · Boiler
- Condensate not draining, burner shuts down Viessmann · Boiler
- DHW hygiene function (B1HE only) Viessmann · Boiler
- Direct vent gasket selection Viessmann · Boiler
- Do not run the control without the junction box lid Viessmann · Boiler
- Electrical installation requirements Viessmann · Boiler
- Entering the service menu Viessmann · Boiler
- Field-supplied controls and OpenTherm Viessmann · Boiler
- Fitting the programming unit at the top Viessmann · Boiler
- Flue gas temperature rating Viessmann · Boiler
- Flue products and nearby building materials Viessmann · Boiler
- Front panel refit Viessmann · Boiler
- Hygiene and DHW temperature advice Viessmann · Boiler
- Instructing the system user Viessmann · Boiler
- Keep combustion and ventilation air free of contaminants Viessmann · Boiler
- Lag boilers lose contact with lead boiler (cascade) Viessmann · Boiler
- Leak test the gas supply before start-up Viessmann · Boiler
- Marine or coastal installations Viessmann · Boiler
- Mixing valves on condensing systems Viessmann · Boiler
- Opening the junction box and moving the control base to service position Viessmann · Boiler
- Poor WiFi connection to the boiler Viessmann · Boiler
- Protect the gas ignition components from water Viessmann · Boiler
- Refitting the junction box lid, control base, front panel and programming unit (programming unit at bottom) Viessmann · Boiler
- Reinstalling the burner after service Viessmann · Boiler
- Replace the flow limiter Viessmann · Boiler
- Reset faults with the tr rotary selector Viessmann · Boiler
- Resetting the maintenance display Viessmann · Boiler
- Routing low voltage and 120 V cables Viessmann · Boiler
- Setting lower and upper heating output for combustion testing Viessmann · Boiler
- Tank sensor or aquastat connection (B1HE) Viessmann · Boiler
- Underfloor tubing without oxygen barrier Viessmann · Boiler
- WiFi router and network requirements Viessmann · Boiler
- Wiring a floating call for heat contact Viessmann · Boiler
All Viessmann Boiler error codes →
Homeowner help: Boiler Not Heating: What to Check
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.