Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Noritz Error Code 14: Thermal fuse failure (Tankless)

Updated · by Aurora Star Tech Inc.

Noritz error code 14 on a tankless water heater means: Thermal fuse failure. It is also called Noritz diagnostic code 14.

High severityTankless Water HeaterNoritz NRC/NRCP · Noritz NRCR

Homeowner? What Noritz code 14 means for you

Call a technician Your tankless water heater is reporting: Thermal fuse failure. The tankless water heater has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check that gas reaches the house: other gas appliances work, or the propane tank is not empty.
  • Make sure the heater is plugged in and its breaker is on. In winter, keep the power on: it protects the unit from freezing.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the hot and cold water valves under the heater are fully open.
  • If you have a remote controller, turn it off and on once. If the code comes back, call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Noritz error code 14 mean?

The thermal fuse around the heat exchanger/combustion chamber has opened because of overheating. The NRCR deck lists 14 among the codes caused by hard water and scale.

Applies to: Noritz NRC/NRCP and older non-premix, and NRCR

Common causes of Noritz code 14

  • Scale build-up in the heat exchanger from hard water
  • Poor combustion overheating the combustion chamber
  • Failed thermal fuse or broken wiring
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Noritz models that use code 14

N-0841MCN-0841MC-DVN-0842MCN-0842MC-DVNRC111-DVNRC111-SVNRCR92DVNRCR111DV

Other Noritz Tankless codes

CodeMeaning
06Low recirculation flow (warning only)
10Abnormal combustion (NRCR, gas supply related)
11Ignition failure (no flame detected)
12Flame loss (repeated)
16Abnormally high outlet temperature
20High limit switch tripped
29Condensate collector water level abnormal
061Recirculation abnormality (sub-code of 06)
062Recirculation abnormality (sub-code of 06)
63Recirculation abnormality (no recirculation flow)
65Main water control servo abnormality
66Bypass water control servo abnormality

All Noritz Tankless Water Heater error codes →

Noritz code 14: homeowner questions

What does Noritz code 14 mean?

Thermal fuse failure. The thermal fuse around the heat exchanger/combustion chamber has opened because of overheating. The NRCR deck lists 14 among the codes caused by hard water and scale.

Is it safe to keep using my tankless water heater with code 14?

It depends on the cause. The tankless water heater has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Noritz code 14 myself?

You can try one reset (power off for 30 seconds, then on). If Noritz code 14 comes back, the cause is still there and a licensed technician should check it.

Who can fix Noritz code 14 near me?

Aurora Star Tech Inc. repairs Noritz tankless water heaters in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Tankless Water Heater No Hot Water: What to Check

Troubleshooting guides

Source: Noritz Residential Level 2 Maintenance & Troubleshooting (NRC/NRCP and older, R2 V1), 14, 16, 20 error codes, p.8; Noritz NRCR Pro training (NRCR92/NRCR111, Printable V3), Poor water quality issues, p.32. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.