Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Noritz Tankless Water Heater: Cleaning the fan and burner – Noritz EZ/NRCR/CDV

Updated · by Aurora Star Tech Inc.

Cleaning the fan and burner - Noritz EZ/NRCR/CDV on a Noritz tankless water heater: Premix units: a dirty fan or venturi lowers air and gas to the burner (code 90 on older installs).

Homeowner with a tankless water heater problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Noritz premix: EZ, NRCR, NCC199CDV

Common causes of cleaning the fan and burner - noritz ez/nrcr/cdv

  • Dust and lint drawn in with combustion air

How to fix cleaning the fan and burner - noritz ez/nrcr/cdv: step by step

  1. WARNING: Shut off the gas and power first.
  2. Remove the mounting bracket (2 screws).
  3. Remove the c-clip and carefully pull the gas valve off the venturi; do not damage the o-ring.
  4. Unplug the fan harness and remove the 4 screws holding the fan to the burner.
  5. Take out the fan and venturi, then separate the venturi from the fan.
  6. Clean the fan using a plastic brush, vacuum or compressed air. Never take the fan housing apart; if it won't come clean, replace the fan.
  7. Clean the burner with a vacuum only. Never use an air compressor on the burner; it can damage the burner mesh.
  8. Reassemble with the gas connection lined up with the triangle on the fan housing, keeping all o-rings and gaskets in place; leak test the gas connection.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Noritz Tankless Water Heater codes

Models

Noritz EZ

EZ71DVEZ98DVEZ111DV

Noritz NRC/NRCP

N-0841MCN-0841MC-DVN-0842MCN-0842MC-DVNRC111-DVNRC111-SV

Noritz CDV

NCC199CDV

Noritz NRCR

NRCR92DVNRCR111DV

Source: Noritz EZ/NRCR/CDV Level 2 Maintenance & Troubleshooting (Premix R2 V2), Cleaning fan & burner, p.7-10. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977