Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Noritz Tankless Water Heater: Descaling (flushing) the heat exchanger – Noritz

Updated · by Aurora Star Tech Inc.

Descaling (flushing) the heat exchanger - Noritz on a Noritz tankless water heater: Periodic descale for hard water. Scale causes 14/16/20/65 codes, unstable temperature, overheated water and clogged filters. A descale takes about 1 hour.

Homeowner with a tankless water heater problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: All Noritz residential tankless (EZ, NRCR, NCC199CDV, NRC/NRCP)

Common causes of descaling (flushing) the heat exchanger - noritz

  • Hard water above 12 gpg (200 mg/L)
  • No softener or scale inhibitor

How to fix descaling (flushing) the heat exchanger - noritz: step by step

  1. Equipment: 5 gallon bucket, 1/6 hp submersible pump, 2 flexible hoses and a 50/50 mix of water and calcium/lime/rust remover (Noritz kit DSCL-KIT).
  2. Units since 2016 have a Flush Mode for descaling (NC380-SV has no flush connector). On EZ/NRCR Pro there is no flush connector: start Scale Flushing from the EZ Start Plus app or display with the power button off.
  3. Turn off power and gas, close the water valves, connect the hoses to the isolation valve ports and circulate the solution per the installation manual.
  4. Use the hour to check intake/exhaust terminations, the internal intake filter, clean the ignition/flame rods and clean the fan and burner.
  5. Flush with clean water, clean the inlet filter (and NRCR return filter), restore water, gas and power.
  6. If the service reminder (C1#) was on, it clears after a correct flush.
  7. Recommend a softener or Scale Shield; treated water prevents scale better than descaling.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Noritz Tankless Water Heater codes

Models

Noritz EZ

EZ71DVEZ98DVEZ111DV

Noritz NRC/NRCP

N-0841MCN-0841MC-DVN-0842MCN-0842MC-DVNRC111-DVNRC111-SV

Noritz CDV

NCC199CDV

Noritz NRCR

NRCR92DVNRCR111DV

Source: Noritz EZ/NRCR/CDV Level 2 Maintenance & Troubleshooting (Premix R2 V2), Water quality and descale procedure, p.3-6; Noritz Residential Level 2 Maintenance & Troubleshooting (NRC/NRCP and older, R2 V1), Descaling/flushing, p.2-4; Noritz NRCR Pro training (NRCR92/NRCR111, Printable V3), Service reminder / descaling, p.31-33; Noritz EZ/NRCR Owner's Guide (Rev. 10-25), Water quality and maintenance, p.28. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977