Applies to: All Noritz residential tankless (EZ, NRCR, NCC199CDV, NRC/NRCP)

Common causes of heater does not fire when hot water is opened - noritz tankless

  • Flow below activation rate
  • Reversed or crossed plumbing
  • Clogged inlet filter
  • Power off or gas off
  • Frozen unit

How to fix heater does not fire when hot water is opened - noritz tankless: step by step

  1. Read MM14 to see if the unit sees flow; it needs about 0.5 GPM (EZ/NRCR: 0.4 GPM to start).
  2. Check for reversed hot/cold connections or crossed pipes (owner's guide).
  3. Close the valves and clean the water drain valve / inlet filter (NRCR: also the return filter).
  4. Check the power button/switch and the 120 VAC supply.
  5. Check gas valves are open and gas is available (other appliances work, LP tank not empty).
  6. If it tries to light but fails, reset and retry (air in gas line), then check inlet gas pressure.
  7. A recirculation pump alone may not move enough flow to fire the unit; check with MM14.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Noritz Tankless Water Heater codes

Models

Noritz EZ

EZ71DVEZ98DVEZ111DV

Noritz NRC/NRCP

N-0841MCN-0841MC-DVN-0842MCN-0842MC-DVNRC111-DVNRC111-SV

Noritz CDV

NCC199CDV

Noritz NRCR

NRCR92DVNRCR111DV

Source: Noritz EZ/NRCR/CDV Level 2 Maintenance & Troubleshooting (Premix R2 V2), MM14 flow rate, p.19; Noritz Residential Level 2 Maintenance & Troubleshooting (NRC/NRCP and older, R2 V1), Flow rate, p.13; Noritz EZ/NRCR Owner's Guide (Rev. 10-25), Troubleshooting, p.28-29. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977