Noritz Error Code 29: Condensate collector water level abnormal (Tankless)

Updated · by Aurora Star Tech Inc.

Noritz error code 29 on a tankless water heater means: Condensate collector water level abnormal. It is also called Noritz diagnostic code 29.

Medium severityTankless Water HeaterNoritz NRC/NRCP

Homeowner? What Noritz code 29 means for you

Check, then call Your tankless water heater is reporting: Condensate collector water level abnormal. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check that gas reaches the house: other gas appliances work, or the propane tank is not empty.
  • Make sure the heater is plugged in and its breaker is on. In winter, keep the power on: it protects the unit from freezing.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the hot and cold water valves under the heater are fully open.
  • If you have a remote controller, turn it off and on once. If the code comes back, call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Noritz error code 29 mean?

Condensate is backing up in the condensate collector of a non-premix condensing unit (NRC/NRCP). The deck only covers the drain line routing.

Applies to: Noritz NRC/NRCP and older non-premix condensing units

Common causes of Noritz code 29

  • Drain line smaller than 1/2 in., too long or with flat horizontal runs
  • Drain line pitched up after a horizontal section, or a trap formed in the line
  • Valves added to the drain line, or no air gap at the end

A technician checks these and 1 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Noritz models that use code 29

N-0841MCN-0841MC-DVN-0842MCN-0842MC-DVNRC111-DVNRC111-SV

Other Noritz Tankless codes

CodeMeaning
10Abnormal combustion (NRCR, gas supply related)
11Ignition failure (no flame detected)
12Flame loss (repeated)
14Thermal fuse failure
16Abnormally high outlet temperature
20High limit switch tripped
061Recirculation abnormality (sub-code of 06)
062Recirculation abnormality (sub-code of 06)
63Recirculation abnormality (no recirculation flow)
65Main water control servo abnormality
66Bypass water control servo abnormality
73Circuit board setting abnormality

All Noritz Tankless Water Heater error codes →

Noritz code 29: homeowner questions

What does Noritz code 29 mean?

Condensate collector water level abnormal. Condensate is backing up in the condensate collector of a non-premix condensing unit (NRC/NRCP). The deck only covers the drain line routing.

Is it safe to keep using my tankless water heater with code 29?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Noritz code 29 myself?

You can try one reset (power off for 30 seconds, then on). If Noritz code 29 comes back, the cause is still there and a licensed technician should check it.

Who can fix Noritz code 29 near me?

Aurora Star Tech Inc. repairs Noritz tankless water heaters in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Tankless Water Heater No Hot Water: What to Check

Troubleshooting guides

Source: Noritz Residential Level 2 Maintenance & Troubleshooting (NRC/NRCP and older, R2 V1), 29 error code, p.8. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977