Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Noritz Error Code 062: Recirculation abnormality (sub-code of 06) (Tankless)

Updated · by Aurora Star Tech Inc.

Noritz error code 062 on a tankless water heater means: Recirculation abnormality (sub-code of 06). It is also called Noritz diagnostic code 062.

Low severityTankless Water HeaterNoritz NRCR

Homeowner? What Noritz code 062 means for you

Usually minor Your tankless water heater is reporting: Recirculation abnormality (sub-code of 06). This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check that gas reaches the house: other gas appliances work, or the propane tank is not empty.
  • Make sure the heater is plugged in and its breaker is on. In winter, keep the power on: it protects the unit from freezing.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the hot and cold water valves under the heater are fully open.
  • If you have a remote controller, turn it off and on once. If the code comes back, call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Noritz error code 062 mean?

NRCR only. Listed with 06 in the owner's guide as recirculation abnormality.

Applies to: Noritz NRCR92 / NRCR111

Common causes of Noritz code 062

  • Clogged return line filter
  • Clogged crossover valve filter
  • Air in the return line
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Noritz models that use code 062

NRCR92DVNRCR111DV

Other Noritz Tankless codes

CodeMeaning
12Flame loss (repeated)
14Thermal fuse failure
16Abnormally high outlet temperature
20High limit switch tripped
29Condensate collector water level abnormal
061Recirculation abnormality (sub-code of 06)
63Recirculation abnormality (no recirculation flow)
65Main water control servo abnormality
66Bypass water control servo abnormality
73Circuit board setting abnormality
90Combustion abnormality
91Gas conversion not done correctly

All Noritz Tankless Water Heater error codes →

Noritz code 062: homeowner questions

What does Noritz code 062 mean?

Recirculation abnormality (sub-code of 06). NRCR only. Listed with 06 in the owner's guide as recirculation abnormality.

Is it safe to keep using my tankless water heater with code 062?

Usually yes. Code 062 is normally minor, but if it keeps coming back have it checked.

Can I reset Noritz code 062 myself?

You can try one reset (power off for 30 seconds, then on). If Noritz code 062 comes back, the cause is still there and a licensed technician should check it.

Who can fix Noritz code 062 near me?

Aurora Star Tech Inc. repairs Noritz tankless water heaters in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Tankless Water Heater No Hot Water: What to Check

Troubleshooting guides

Source: Noritz EZ/NRCR Owner's Guide (Rev. 10-25), Checking for error conditions, p.31. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service