Midea Error Codes & Diagnostic Codes

Updated · by Aurora Star Tech Inc.

Midea error codes and diagnostic codes: look up a code to see what it means, the likely causes and the steps to fix it.

Midea error codes by equipment type

Midea Furnace error codes

CodeMeaning
E1Low-fire pressure switch stuck closed

Midea Heat Pump error codes

CodeMeaning
DFDF shown on outdoor display - normal, not a malfunction
EC07Outdoor DC fan motor fault / speed out of control
EC50outdoor temperature sensor fault
EC51Outdoor EEPROM error
EC52condenser coil temperature sensor fault
EC53outdoor ambient temperature sensor fault
EC54Discharge temperature sensor (TP) open/short
EC71Outdoor DC fan motor over-current
EC72Outdoor DC fan motor lack-phase
EL01Indoor/outdoor communication error
EL16Main board to transit board communication error
FCFC shown on outdoor display - normal, not a malfunction
LC06Inverter module (IPM) high temperature protection
PC0ACondenser high temperature protection
PC0FPFC module protection
PC0LOutdoor unit low-temperature protection
PC00Inverter module (IPM) protection
PC02Compressor top temperature protection
PC06Compressor discharge temperature protection
PC08Outdoor over-current protection
PC10Outdoor low AC voltage protection
PC11Outdoor DC bus high voltage protection
PC12DC bus high voltage protection / 341 MCE error
PC30System high pressure protection
PC31System low pressure protection
PC40Main chip to compressor-driver chip communication error
PC42Compressor start failure
PC43Compressor lack-phase protection
PC44Outdoor unit zero-speed protection
PC45Outdoor IR chip drive failure
PC46Compressor speed out of control
PC49Compressor over-current failure
PH90Evaporator high temperature protection
PH91Evaporator low temperature protection

Midea Mini-Split error codes

CodeMeaning
--Indoor units mode conflict
APWi-Fi pairing (AP mode)
CLFilter cleaning reminder / Active Clean
CPRemote switched off
d1Demand response signal DR1 received
d2Demand response signal DR2 received
d3Demand response signal DR3 received
dEDemand response input error
dFDefrost
E-C-OECO mode
E1Indoor / outdoor communication error
EC07Outdoor fan speed out of range
EC50Outdoor temperature sensor fault
EC51Outdoor EEPROM error
EC52Condenser coil sensor (T3) fault
EC53Outdoor ambient sensor (T4) fault
EC54Discharge temperature sensor (TP/T5) fault
EC55IPM temperature sensor fault
EC56Indoor coil outlet sensor (T2B) fault
EC57Refrigerant pipe sensor fault
EC71Outdoor fan motor over-current
EC72Outdoor fan motor phase loss
EH0AIndoor EEPROM error
EH0bIndoor PCB to display board communication error
EH00Indoor EEPROM error
EH02Zero-crossing signal error
EH03Indoor fan speed out of range
EH30Indoor external fan low voltage
EH31Indoor external fan over voltage
Eh60Room sensor (T1) fault
Eh61Indoor coil sensor (T2) fault
EL0CRefrigerant leak detected
EL01Indoor / outdoor communication error
F0Current overload protection
F1Outdoor ambient sensor (T4) fault
F2Condenser coil sensor (T3) fault
F3Discharge sensor (T5) fault
F4Outdoor EEPROM error
F5Outdoor fan speed out of control
FbVapor injection inlet sensor fault
FCForced cooling
FdVapor injection outlet sensor fault
FH 0dFault - see outdoor unit
FL14Indoor and outdoor units not compatible
FPLow-temperature heating (8 C mode)
J0Outdoor coil overheat in cooling
J1Indoor coil temperature protection in heating
J2Discharge temperature protection
J3PFC module protection
J4Main board to IPM board communication error
J5High pressure protection
J6Low pressure protection
J8AC voltage protection
LC01Speed limited by condenser temperature
LC02Speed limited by discharge temperature
LC03Speed limited by current
LC05Speed limited by voltage
LC06IPM high temperature / PFC frequency limit
LH00Speed limited by indoor coil temperature
LH07Speed limited by remote
LLControls locked
nANo fault
nFFilter replacement reminder
ODU --Outdoor board standby
ODU CEAutomatic wiring / piping check running
ODU E0Outdoor EEPROM error (outdoor board)
ODU E2Indoor / outdoor communication error (outdoor board)
ODU E3IPM to main board communication error (outdoor board)
ODU E4Outdoor or T2B sensor fault (outdoor board)
ODU E5Over or under voltage (outdoor board)
ODU E6PFC module protection (outdoor board)
ODU E8Outdoor fan speed fault (outdoor board)
ODU EdAdapter / inverter board to main board communication error
ODU F1Zone A coil outlet sensor (T2B-A) fault
ODU F2Zone B coil outlet sensor (T2B-B) fault
ODU F3Zone C coil outlet sensor (T2B-C) fault
ODU F4Zone D coil outlet sensor (T2B-D) fault
ODU F5Zone E coil outlet sensor (T2B-E) fault
ODU F6Zone F coil outlet sensor (T2B-F) fault
ODU Hz readoutCompressor running frequency
ODU LCLow ambient cooling mode
ODU LPLow outdoor temperature protection (outdoor board)
ODU P0Compressor top overheat (outdoor board)
ODU P1High pressure protection (outdoor board)
ODU P2Low pressure protection (outdoor board)
ODU P3Current overload (outdoor board)
ODU P4Discharge temperature protection (outdoor board)
ODU P5Condenser high temperature (outdoor board)
ODU P6Inverter module (IPM) fault (outdoor board)
ODU PHCompressor pre-heat
ODU ROOil return cycle
OffTimer off
OnTimer on
P0Inverter module (IPM) fault
P1Over or under voltage protection
P2Compressor top overheat (OLP)
P3Low outdoor temperature cut-off in heating
P4Compressor drive fault
P7IPM temperature sensor fault
PC0ACondenser high temperature protection
PC0FPFC module protection
PC0LOutdoor temperature too low
PC00Inverter module (IPM) protection
PC02Compressor top overheat (OLP)
PC03Pressure protection
PC04Inverter compressor drive error
PC06Discharge temperature protection
PC08Outdoor over-current protection
PC10Low AC supply voltage
PC11AC supply voltage protection (over voltage)
PC12DC bus high voltage / 341 MCE error
PC30High pressure protection
PC31Low pressure protection
PC40Main chip to compressor drive chip communication error
PC41Current input detection protection
PC42Compressor start failure
PC43Compressor phase loss
PC44Zero speed protection
PC45Compressor drive chip (IR / 341 PWM) failure
PC46Compressor speed out of control
PC49Compressor over-current
PCA1Refrigerant pipe condensation protection
PH09Anti-cold-air in heating
PH90Evaporator coil too hot
PH91Evaporator coil too cold
SCSelf clean running
SDPower abnormal detection

Find codes by Midea model

Midea 96% AFUE A2L Gas Furnace (BGH96M)

BGH96M060B3ABGH96M080B3ABGH96M080C4ABGH96M100C5ABGH96M100D5ABGH96M120D5A

Midea DLCM(R/H)B multi-zone outdoor

DLCMHBH24CAKDLCMHBH30DAKDLCMHBH36DAKDLCMHBH48EAKDLCMRBH18BAKDLCMRBH36DAKDLCMRBH48EAK

Midea DLCURA ducted single-zone inverter heat pump (outdoor)

DLCURAH18AAKDLCURAH18ABKDLCURAH24AAKDLCURAH24ABKDLCURAH30AAKDLCURAH30ABKDLCURAH36AAKDLCURAH36ABKDLCURAH48AAKDLCURAH48ABKDLCURAH60AAKDLCURAH60ABK

Midea DLFSHBH wall indoor (DLCM multi-zone)

DLFSHBH09XAKDLFSHBH12XAJDLFSHBH12XAKDLFSHBH18XAKDLFSHBH24XAK

Midea troubleshooting guides

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.