Midea Furnace: Resetting a locked-out furnace

Updated · by Aurora Star Tech Inc.

Resetting a locked-out furnace on a Midea furnace: How to clear a lockout after ignition failure on the BGH96M control.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Midea BGH96M 96% AFUE two-stage gas furnaces (060B3A, 080B3A, 080C4A, 100C5A, 100D5A, 120D5A)

Common causes of resetting a locked-out furnace

  • Ignition not achieved after repeated attempts

How to fix resetting a locked-out furnace: step by step

  1. Read and note the diagnostic LED code before resetting.
  2. Option 1: wait - the control automatically resets after 1 hour.
  3. Option 2: interrupt 115 V power to the furnace for 1-20 seconds.
  4. Option 3: lower the thermostat to remove the call for heat for 1-20 seconds.
  5. If it locks out again, troubleshoot the code shown (E7/E8 etc.).
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Midea Furnace codes

Models

BGH96M060B3ABGH96M080B3ABGH96M080C4ABGH96M100C5ABGH96M100D5ABGH96M120D5A

Source: Midea 96% AFUE Gas Furnace (A2L) Troubleshooting Guide, Section 2.2 Resetting From Lockout, p.6. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977