Midea Error Code PC49: Compressor over-current (Mini-Split)

Updated · by Aurora Star Tech Inc.

Midea error code PC49 on a mini-split means: Compressor over-current. It is also called Midea diagnostic code PC49.

High severityMini-SplitMidea DLCM(R/H)B multi-zone outdoor · Midea DLFSHBH wall indoor (DLCM multi-zone)

Homeowner? What Midea code PC49 means for you

Call a technician Your ductless mini-split is reporting: Compressor over-current. The ductless mini-split has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the remote: fresh batteries and the right mode (Cool, Heat or Auto).
  • Check the breaker and the outdoor disconnect; both should be ON.
  • Open the front cover of the indoor unit and rinse the washable filters if they are dusty; let them dry before putting them back.
  • Keep the outdoor unit clear of snow, ice and leaves.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Midea error code PC49 mean?

The compressor drew more current than allowed.

Applies to: DLCM(R/H)B multi-zone outdoor units with DLFSHBH high wall indoor units (Midea, Carrier, Viessmann)

Common causes of Midea code PC49

  • High load / restriction
  • Poor outdoor airflow
  • Bad compressor or PCB
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Midea models that use code PC49

DLCMHBH24CAKDLCMHBH30DAKDLCMHBH36DAKDLCMHBH48EAKDLCMRBH18BAKDLCMRBH36DAKDLCMRBH48EAKDLFSHBH09XAKDLFSHBH12XAJDLFSHBH12XAKDLFSHBH18XAKDLFSHBH24XAK

Other Midea Mini-Split codes

CodeMeaning
PC41Current input detection protection
PC42Compressor start failure
PC43Compressor phase loss
PC44Zero speed protection
PC45Compressor drive chip (IR / 341 PWM) failure
PC46Compressor speed out of control
PCA1Refrigerant pipe condensation protection
PH09Anti-cold-air in heating
PH90Evaporator coil too hot
PH91Evaporator coil too cold
SCSelf clean running
SDPower abnormal detection

All Midea Mini-Split error codes →

Midea code PC49: homeowner questions

What does Midea code PC49 mean?

Compressor over-current. The compressor drew more current than allowed.

Is it safe to keep using my ductless mini-split with code PC49?

It depends on the cause. The ductless mini-split has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Midea code PC49 myself?

You can try one reset (power off for 30 seconds, then on). If Midea code PC49 comes back, the cause is still there and a licensed technician should check it.

Who can fix Midea code PC49 near me?

Aurora Star Tech Inc. repairs Midea ductless mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: DLCMRBH/DLCMHBH Multi-Zone Outdoor Service Manual (sold as Midea, Carrier and Viessmann Vitocal 200-S; Viessmann doc 6225551-03, 12/2024), Table 23 Outdoor Unit Error Display p.26; diagnosis p.64-65; Carrier MS-DLFSHB-01 High Wall Ductless Service Manual (04/2021), Table 9 p.17. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.