Midea Error Code –: Indoor units mode conflict (Mini-Split)

Updated · by Aurora Star Tech Inc.

Midea error code -- on a mini-split means: Indoor units mode conflict. It is also called Midea diagnostic code --.

Low severityMini-SplitMidea DLFSHBH wall indoor (DLCM multi-zone)

Homeowner? What Midea code -- means for you

Usually minor Your ductless mini-split is reporting: Indoor units mode conflict. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the remote: fresh batteries and the right mode (Cool, Heat or Auto).
  • Check the breaker and the outdoor disconnect; both should be ON.
  • Open the front cover of the indoor unit and rinse the washable filters if they are dusty; let them dry before putting them back.
  • Keep the outdoor unit clear of snow, ice and leaves.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Midea error code -- mean?

Multi-zone: one indoor unit asks for heating while another asks for cooling or fan. Heating wins; see the mode conflict guide.

Applies to: DLFSHBH high wall indoor units 09-24K (Midea / Carrier / Viessmann) on DLC multi-zone or single-zone outdoor units

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Midea models that use code --

DLFSHBH09XAKDLFSHBH12XAJDLFSHBH12XAKDLFSHBH18XAKDLFSHBH24XAK

Other Midea Mini-Split codes

CodeMeaning
APWi-Fi pairing (AP mode)
CLFilter cleaning reminder / Active Clean
CPRemote switched off
d1Demand response signal DR1 received
d2Demand response signal DR2 received
d3Demand response signal DR3 received
dEDemand response input error
dFDefrost
E-C-OECO mode
E1Indoor / outdoor communication error
EC07Outdoor fan speed out of range
EC50Outdoor temperature sensor fault

All Midea Mini-Split error codes →

Midea code --: homeowner questions

What does Midea code -- mean?

Indoor units mode conflict. Multi-zone: one indoor unit asks for heating while another asks for cooling or fan. Heating wins; see the mode conflict guide.

Is it safe to keep using my ductless mini-split with code --?

Usually yes. Code -- is normally minor, but if it keeps coming back have it checked.

Can I reset Midea code -- myself?

You can try one reset (power off for 30 seconds, then on). If Midea code -- comes back, the cause is still there and a licensed technician should check it.

Who can fix Midea code -- near me?

Aurora Star Tech Inc. repairs Midea ductless mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Carrier MS-DLFSHB-01 High Wall Ductless Service Manual (04/2021), Table 9 p.17. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.