Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Midea Error Code PC0A: Condenser high temperature protection (Mini-Split)

Updated · by Aurora Star Tech Inc.

Midea error code PC0A on a mini-split means: Condenser high temperature protection. It is also called Midea diagnostic code PC0A.

Medium severityMini-SplitMidea DLCM(R/H)B multi-zone outdoor · Midea DLFSHBH wall indoor (DLCM multi-zone)

Homeowner? What Midea code PC0A means for you

Check, then call Your ductless mini-split is reporting: Condenser high temperature protection. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the remote: fresh batteries and the right mode (Cool, Heat or Auto).
  • Check the breaker and the outdoor disconnect; both should be ON.
  • Open the front cover of the indoor unit and rinse the washable filters if they are dusty; let them dry before putting them back.
  • Keep the outdoor unit clear of snow, ice and leaves.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Midea error code PC0A mean?

Outdoor coil pipe reached 149 F (65 C), so the unit shut off. It restarts below 125.6 F (52 C). Outdoor board shows P5; 48K HH shows J0.

Applies to: DLCM(R/H)B multi-zone outdoor units with DLFSHBH high wall indoor units (Midea, Carrier, Viessmann)

Common causes of Midea code PC0A

  • Bad T3 sensor
  • Dirty coil / poor airflow
  • Outdoor fan problem

A technician checks these and 1 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Midea models that use code PC0A

DLCMHBH24CAKDLCMHBH30DAKDLCMHBH36DAKDLCMHBH48EAKDLCMRBH18BAKDLCMRBH36DAKDLCMRBH48EAKDLFSHBH09XAKDLFSHBH12XAJDLFSHBH12XAKDLFSHBH18XAKDLFSHBH24XAK

Other Midea Mini-Split codes

CodeMeaning
P0Inverter module (IPM) fault
P1Over or under voltage protection
P2Compressor top overheat (OLP)
P3Low outdoor temperature cut-off in heating
P4Compressor drive fault
P7IPM temperature sensor fault
PC0FPFC module protection
PC0LOutdoor temperature too low
PC00Inverter module (IPM) protection
PC02Compressor top overheat (OLP)
PC03Pressure protection
PC04Inverter compressor drive error

All Midea Mini-Split error codes →

Midea code PC0A: homeowner questions

What does Midea code PC0A mean?

Condenser high temperature protection. Outdoor coil pipe reached 149 F (65 C), so the unit shut off. It restarts below 125.6 F (52 C). Outdoor board shows P5; 48K HH shows J0.

Is it safe to keep using my ductless mini-split with code PC0A?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Midea code PC0A myself?

You can try one reset (power off for 30 seconds, then on). If Midea code PC0A comes back, the cause is still there and a licensed technician should check it.

Who can fix Midea code PC0A near me?

Aurora Star Tech Inc. repairs Midea ductless mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: DLCMRBH/DLCMHBH Multi-Zone Outdoor Service Manual (sold as Midea, Carrier and Viessmann Vitocal 200-S; Viessmann doc 6225551-03, 12/2024), Table 23 Outdoor Unit Error Display p.26; diagnosis p.67; Carrier MS-DLFSHB-01 High Wall Ductless Service Manual (04/2021), Table 9 p.17. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977