Midea Error Code PC41: Current input detection protection (Mini-Split)

Updated · by Aurora Star Tech Inc.

Midea error code PC41 on a mini-split means: Current input detection protection. It is also called Midea diagnostic code PC41.

Medium severityMini-SplitMidea DLFSHBH wall indoor (DLCM multi-zone)

Homeowner? What Midea code PC41 means for you

Check, then call Your ductless mini-split is reporting: Current input detection protection. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the remote: fresh batteries and the right mode (Cool, Heat or Auto).
  • Check the breaker and the outdoor disconnect; both should be ON.
  • Open the front cover of the indoor unit and rinse the washable filters if they are dusty; let them dry before putting them back.
  • Keep the outdoor unit clear of snow, ice and leaves.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Midea error code PC41 mean?

Input current detection fault. No flow chart in the manual.

Applies to: DLFSHBH high wall indoor units 09-24K (Midea / Carrier / Viessmann) on DLC multi-zone or single-zone outdoor units

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Midea models that use code PC41

DLFSHBH09XAKDLFSHBH12XAJDLFSHBH12XAKDLFSHBH18XAKDLFSHBH24XAK

Other Midea Mini-Split codes

CodeMeaning
PC10Low AC supply voltage
PC11AC supply voltage protection (over voltage)
PC12DC bus high voltage / 341 MCE error
PC30High pressure protection
PC31Low pressure protection
PC40Main chip to compressor drive chip communication error
PC42Compressor start failure
PC43Compressor phase loss
PC44Zero speed protection
PC45Compressor drive chip (IR / 341 PWM) failure
PC46Compressor speed out of control
PC49Compressor over-current

All Midea Mini-Split error codes →

Midea code PC41: homeowner questions

What does Midea code PC41 mean?

Current input detection protection. Input current detection fault. No flow chart in the manual.

Is it safe to keep using my ductless mini-split with code PC41?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Midea code PC41 myself?

You can try one reset (power off for 30 seconds, then on). If Midea code PC41 comes back, the cause is still there and a licensed technician should check it.

Who can fix Midea code PC41 near me?

Aurora Star Tech Inc. repairs Midea ductless mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Carrier MS-DLFSHB-01 High Wall Ductless Service Manual (04/2021), Table 9 p.17. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.