Midea Error Code PC43: Compressor lack-phase protection (Heat Pump)

Updated · by Aurora Star Tech Inc.

Midea error code PC43 on a heat pump means: Compressor lack-phase protection. It is also called Midea diagnostic code PC43.

High severityHeat PumpMidea DLCURA ducted single-zone inverter heat pump (outdoor)

Homeowner? What Midea code PC43 means for you

Call a technician Your heat pump is reporting: Compressor lack-phase protection. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Midea error code PC43 mean?

One of the compressor phases is missing.

Applies to: DLCURAH18-60 AAK/ABK single-zone heat pump outdoor units (18K-60K, regular and High Heat)

Common causes of Midea code PC43

  • Loose or broken compressor lead
  • Open compressor winding
  • Drive board output fault
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Midea models that use code PC43

DLCURAH18AAKDLCURAH18ABKDLCURAH24AAKDLCURAH24ABKDLCURAH30AAKDLCURAH30ABKDLCURAH36AAKDLCURAH36ABKDLCURAH48AAKDLCURAH48ABKDLCURAH60AAKDLCURAH60ABK

Other Midea Heat Pump codes

CodeMeaning
PC11Outdoor DC bus high voltage protection
PC12DC bus high voltage protection / 341 MCE error
PC30System high pressure protection
PC31System low pressure protection
PC40Main chip to compressor-driver chip communication error
PC42Compressor start failure
PC44Outdoor unit zero-speed protection
PC45Outdoor IR chip drive failure
PC46Compressor speed out of control
PC49Compressor over-current failure
PH90Evaporator high temperature protection
PH91Evaporator low temperature protection

All Midea Heat Pump error codes →

Midea code PC43: homeowner questions

What does Midea code PC43 mean?

Compressor lack-phase protection. One of the compressor phases is missing.

Is it safe to keep using my heat pump with code PC43?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Midea code PC43 myself?

You can try one reset (power off for 30 seconds, then on). If Midea code PC43 comes back, the cause is still there and a licensed technician should check it.

Who can fix Midea code PC43 near me?

Aurora Star Tech Inc. repairs Midea heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Source: Midea/Carrier DLCURA Installation Instructions (Catalog DLCURA-03SI), Table 11 Outdoor Unit Diagnostic Codes, p.19. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977