Midea Error Code LC06: IPM high temperature / PFC frequency limit (Mini-Split)
Midea error code LC06 on a mini-split means: IPM high temperature / PFC frequency limit. It is also called Midea diagnostic code LC06.
Homeowner? What Midea code LC06 means for you
Check, then call Your ductless mini-split is reporting: IPM high temperature / PFC frequency limit. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.
Safe things you can check yourself
- Check the remote: fresh batteries and the right mode (Cool, Heat or Auto).
- Check the breaker and the outdoor disconnect; both should be ON.
- Open the front cover of the indoor unit and rinse the washable filters if they are dusty; let them dry before putting them back.
- Keep the outdoor unit clear of snow, ice and leaves.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Midea error code LC06 mean?
Outdoor manual: IPM module overheat protection. Indoor manual: compressor speed limited because of the PFC. Check which applies by the unit's behaviour (stop vs slow-down).
Applies to: DLCM(R/H)B multi-zone outdoor units with DLFSHBH high wall indoor units (Midea, Carrier, Viessmann)
Common causes of Midea code LC06
- IPM heat sink loose / no thermal paste
- Electric box mounted wrong
Midea models that use code LC06
DLCMHBH24CAKDLCMHBH30DAKDLCMHBH36DAKDLCMHBH48EAKDLCMRBH18BAKDLCMRBH36DAKDLCMRBH48EAKDLFSHBH09XAKDLFSHBH12XAJDLFSHBH12XAKDLFSHBH18XAKDLFSHBH24XAK
Other Midea Mini-Split codes
All Midea Mini-Split error codes →
Midea code LC06: homeowner questions
What does Midea code LC06 mean?
IPM high temperature / PFC frequency limit. Outdoor manual: IPM module overheat protection. Indoor manual: compressor speed limited because of the PFC. Check which applies by the unit's behaviour (stop vs slow-down).
Is it safe to keep using my ductless mini-split with code LC06?
It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.
Can I reset Midea code LC06 myself?
You can try one reset (power off for 30 seconds, then on). If Midea code LC06 comes back, the cause is still there and a licensed technician should check it.
Who can fix Midea code LC06 near me?
Aurora Star Tech Inc. repairs Midea ductless mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air
Troubleshooting guides
- Indoor unit leaking water All brands · Mini-Split
- Poor capacity / high head All brands · Mini-Split
- Water leaking All brands · Mini-Split
- Discharge the inverter capacitors before service Midea · Mini-Split
- Display shows a strange code or does not answer the remote - DLFSHB indoor Midea · Mini-Split
- Multi-zone: one room heats, another will not cool - DLC multi-zone Midea · Mini-Split
- Read live data with the outdoor check button (SW1) Midea · Mini-Split
- Run the automatic wiring / piping correction Midea · Mini-Split
Source: DLCMRBH/DLCMHBH Multi-Zone Outdoor Service Manual (sold as Midea, Carrier and Viessmann Vitocal 200-S; Viessmann doc 6225551-03, 12/2024), Table 23 Outdoor Unit Error Display p.26; diagnosis p.44; Carrier MS-DLFSHB-01 High Wall Ductless Service Manual (04/2021), Table 9 p.17. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.