Midea Error Code LC06: IPM high temperature / PFC frequency limit (Mini-Split)

Updated · by Aurora Star Tech Inc.

Midea error code LC06 on a mini-split means: IPM high temperature / PFC frequency limit. It is also called Midea diagnostic code LC06.

Medium severityMini-SplitMidea DLCM(R/H)B multi-zone outdoor · Midea DLFSHBH wall indoor (DLCM multi-zone)

Homeowner? What Midea code LC06 means for you

Check, then call Your ductless mini-split is reporting: IPM high temperature / PFC frequency limit. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the remote: fresh batteries and the right mode (Cool, Heat or Auto).
  • Check the breaker and the outdoor disconnect; both should be ON.
  • Open the front cover of the indoor unit and rinse the washable filters if they are dusty; let them dry before putting them back.
  • Keep the outdoor unit clear of snow, ice and leaves.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Midea error code LC06 mean?

Outdoor manual: IPM module overheat protection. Indoor manual: compressor speed limited because of the PFC. Check which applies by the unit's behaviour (stop vs slow-down).

Applies to: DLCM(R/H)B multi-zone outdoor units with DLFSHBH high wall indoor units (Midea, Carrier, Viessmann)

Common causes of Midea code LC06

  • IPM heat sink loose / no thermal paste
  • Electric box mounted wrong
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Midea models that use code LC06

DLCMHBH24CAKDLCMHBH30DAKDLCMHBH36DAKDLCMHBH48EAKDLCMRBH18BAKDLCMRBH36DAKDLCMRBH48EAKDLFSHBH09XAKDLFSHBH12XAJDLFSHBH12XAKDLFSHBH18XAKDLFSHBH24XAK

Other Midea Mini-Split codes

CodeMeaning
J6Low pressure protection
J8AC voltage protection
LC01Speed limited by condenser temperature
LC02Speed limited by discharge temperature
LC03Speed limited by current
LC05Speed limited by voltage
LH00Speed limited by indoor coil temperature
LH07Speed limited by remote
LLControls locked
nANo fault
nFFilter replacement reminder
ODU --Outdoor board standby

All Midea Mini-Split error codes →

Midea code LC06: homeowner questions

What does Midea code LC06 mean?

IPM high temperature / PFC frequency limit. Outdoor manual: IPM module overheat protection. Indoor manual: compressor speed limited because of the PFC. Check which applies by the unit's behaviour (stop vs slow-down).

Is it safe to keep using my ductless mini-split with code LC06?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Midea code LC06 myself?

You can try one reset (power off for 30 seconds, then on). If Midea code LC06 comes back, the cause is still there and a licensed technician should check it.

Who can fix Midea code LC06 near me?

Aurora Star Tech Inc. repairs Midea ductless mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: DLCMRBH/DLCMHBH Multi-Zone Outdoor Service Manual (sold as Midea, Carrier and Viessmann Vitocal 200-S; Viessmann doc 6225551-03, 12/2024), Table 23 Outdoor Unit Error Display p.26; diagnosis p.44; Carrier MS-DLFSHB-01 High Wall Ductless Service Manual (04/2021), Table 9 p.17. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977