KeepRite Heat Pump Error Codes

Updated · by Aurora Star Tech Inc.

33 KeepRite Heat Pump error codes and diagnostic codes, with causes and troubleshooting steps for each. Select a code, or find your model below.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

KeepRite Heat Pump error codes list

CodeMeaningSeverity
16Lost communication with wall controlMedium
25Model plug missing or invalidHigh
31High pressure switch openHigh
32Low pressure switch openHigh
45Outdoor control board failureHigh
46Brown-out (low voltage)Medium
47No 230 V at the unitHigh
53Outdoor air temperature sensor faultMedium
55Outdoor coil sensor faultMedium
56Air and coil sensors disagreeMedium
71Low stage thermal cutoutHigh
72Compressor thermal cutout (two-stage: high stage)High
73Contactor stuck closedHigh
74No 230 V at compressorHigh
81Low stage thermal lockoutHigh
82Thermal lockout (two-stage: high stage)High
83Low pressure lockoutHigh
84High pressure lockoutHigh
Amber 1 flashRunning - cooling / low stage (normal)Low
Amber 2 flashesHigh stage running (normal)Low
Amber 3 flashesOutdoor fan delay after defrost is on (20 s)Low
Amber 4 flashesOutdoor fan delay after defrost is defeatedLow
Amber 5 flashesBrown-out protection turned off (user setting)Low
Amber 6 flashesBrown-out protection active (user setting)Low
Amber LED offStandby - no call (2-wire hookup or indoor unit unpowered)Low
Amber LED on solidStandby - no call (communicating)Low
Brown-out defeat toggleTurn 230 V brown-out protection off or onLow
Defrost speed-up pinsSpeed up the defrost timer for testingLow
Fan delay defeat toggleSwitch the post-defrost outdoor fan delay off or onLow
Forced defrost pinsForce a defrost cycle / skip the 5-minute delayLow
Phase monitor LED flashing3-phase monitor - phase reversalHigh
Phase monitor LED off3-phase monitor - no call for compressorLow
Phase monitor LED on3-phase monitor - phases OKLow

Find codes by KeepRite model

KeepRite *CA/*CH Two-Stage Communicating

*CH624*CH636*CH648*CH660*CH924*CH936*CH948*CH960

KeepRite *SA/*SH Single-Stage Communicating

*SH4*SH5*SH6

KeepRite N4H4/R4H4/WCH4/NXH5 Heat Pump

N4H4NXH5R4H4R4H449WCH4

Heat Pump troubleshooting guides

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977