KeepRite Error Code Amber LED off: Standby – no call (2-wire hookup or indoor unit unpowered) (Heat Pump)

Updated · by Aurora Star Tech Inc.

KeepRite error code Amber LED off on a heat pump means: Standby - no call (2-wire hookup or indoor unit unpowered). It is also called KeepRite diagnostic code Amber LED off.

Low severityHeat PumpKeepRite *SA/*SH Single-Stage Communicating

Homeowner? What KeepRite code Amber LED off means for you

Usually minor Your heat pump is reporting: Standby - no call (2-wire hookup or indoor unit unpowered). This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does KeepRite error code Amber LED off mean?

The amber status LED is dark. With only two thermostat wires the board loses power whenever there is no call, so no flash codes can be shown. It also looks like this if the indoor unit has no power. Normally nothing is wrong.

Applies to: *SA/*SH single-stage communicating board

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

KeepRite models that use code Amber LED off

*SH4*SH5*SH6

Other KeepRite Heat Pump codes

CodeMeaning
Amber 1 flashRunning - cooling / low stage (normal)
Amber 2 flashesHigh stage running (normal)
Amber 3 flashesOutdoor fan delay after defrost is on (20 s)
Amber 4 flashesOutdoor fan delay after defrost is defeated
Amber 5 flashesBrown-out protection turned off (user setting)
Amber 6 flashesBrown-out protection active (user setting)
Amber LED on solidStandby - no call (communicating)
Brown-out defeat toggleTurn 230 V brown-out protection off or on
Defrost speed-up pinsSpeed up the defrost timer for testing
Fan delay defeat toggleSwitch the post-defrost outdoor fan delay off or on
Forced defrost pinsForce a defrost cycle / skip the 5-minute delay
Phase monitor LED flashing3-phase monitor - phase reversal

All KeepRite Heat Pump error codes →

KeepRite code Amber LED off: homeowner questions

What does KeepRite code Amber LED off mean?

Standby - no call (2-wire hookup or indoor unit unpowered). The amber status LED is dark. With only two thermostat wires the board loses power whenever there is no call, so no flash codes can be shown. It also looks like this if the indoor unit has no power. Normally nothing is wrong.

Is it safe to keep using my heat pump with code Amber LED off?

Usually yes. Code Amber LED off is normally minor, but if it keeps coming back have it checked.

Can I reset KeepRite code Amber LED off myself?

You can try one reset (power off for 30 seconds, then on). If KeepRite code Amber LED off comes back, the cause is still there and a licensed technician should check it.

Who can fix KeepRite code Amber LED off near me?

Aurora Star Tech Inc. repairs KeepRite heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: KeepRite ICP split A-C + HP (R-410A & R-22) Application Guideline and Service Manual 421 08 5400 04, Table 13 Status Codes, p.46-47. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.