KeepRite Error Code Forced defrost pins: Force a defrost cycle / skip the 5-minute delay (Heat Pump)

Updated · by Aurora Star Tech Inc.

KeepRite error code Forced defrost pins on a heat pump means: Force a defrost cycle / skip the 5-minute delay. It is also called KeepRite diagnostic code Forced defrost pins.

Low severityHeat PumpKeepRite *SA/*SH Single-Stage Communicating · KeepRite *CA/*CH Two-Stage Communicating

Homeowner? What KeepRite code Forced defrost pins means for you

Usually minor Your heat pump is reporting: Force a defrost cycle / skip the 5-minute delay. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does KeepRite error code Forced defrost pins mean?

The heat pump board has a 2-pin header marked FORCED DEFROST. Shorting it for 5 seconds on a non-communicating system starts a defrost (communicating systems start it from the wall control). If the coil is at 32 F or colder and outdoor air is under 50 F a full defrost runs; otherwise only a short 30-second defrost. A quick short and release also skips the 5-minute start delay.

Applies to: Communicating *SA/*SH and *CA/*CH heat pump outdoor boards

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

KeepRite models that use code Forced defrost pins

*CH624*CH636*CH648*CH660*CH924*CH936*CH948*CH960*SH4*SH5*SH6

Other KeepRite Heat Pump codes

CodeMeaning
Amber 6 flashesBrown-out protection active (user setting)
Amber LED offStandby - no call (2-wire hookup or indoor unit unpowered)
Amber LED on solidStandby - no call (communicating)
Brown-out defeat toggleTurn 230 V brown-out protection off or on
Defrost speed-up pinsSpeed up the defrost timer for testing
Fan delay defeat toggleSwitch the post-defrost outdoor fan delay off or on
Phase monitor LED flashing3-phase monitor - phase reversal
Phase monitor LED off3-phase monitor - no call for compressor
Phase monitor LED on3-phase monitor - phases OK

All KeepRite Heat Pump error codes →

KeepRite code Forced defrost pins: homeowner questions

What does KeepRite code Forced defrost pins mean?

Force a defrost cycle / skip the 5-minute delay. The heat pump board has a 2-pin header marked FORCED DEFROST. Shorting it for 5 seconds on a non-communicating system starts a defrost (communicating systems start it from the wall control). If the coil is at 32 F or colder and outdoor…

Is it safe to keep using my heat pump with code Forced defrost pins?

Usually yes. Code Forced defrost pins is normally minor, but if it keeps coming back have it checked.

Can I reset KeepRite code Forced defrost pins myself?

You can try one reset (power off for 30 seconds, then on). If KeepRite code Forced defrost pins comes back, the cause is still there and a licensed technician should check it.

Who can fix KeepRite code Forced defrost pins near me?

Aurora Star Tech Inc. repairs KeepRite heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: KeepRite ICP split A-C + HP (R-410A & R-22) Application Guideline and Service Manual 421 08 5400 04, Forced Defrost, p.44 and p.57. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service