KeepRite Error Code Phase monitor LED off: 3-phase monitor – no call for compressor (Heat Pump)

Updated · by Aurora Star Tech Inc.

KeepRite error code Phase monitor LED off on a heat pump means: 3-phase monitor - no call for compressor. It is also called KeepRite diagnostic code Phase monitor LED off.

Low severityHeat PumpKeepRite N4H4/R4H4/WCH4/NXH5 Heat Pump

Homeowner? What KeepRite code Phase monitor LED off means for you

Usually minor Your heat pump is reporting: 3-phase monitor - no call for compressor. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does KeepRite error code Phase monitor LED off mean?

The phase monitor LED is dark when there is no call for compressor operation. Nothing is wrong.

Applies to: N4H4/R4H4/WCH4/NXH5 three-phase heat pumps

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

KeepRite models that use code Phase monitor LED off

N4H4NXH5R4H4R4H449WCH4

Other KeepRite Heat Pump codes

CodeMeaning
Amber LED on solidStandby - no call (communicating)
Brown-out defeat toggleTurn 230 V brown-out protection off or on
Defrost speed-up pinsSpeed up the defrost timer for testing
Fan delay defeat toggleSwitch the post-defrost outdoor fan delay off or on
Forced defrost pinsForce a defrost cycle / skip the 5-minute delay
Phase monitor LED flashing3-phase monitor - phase reversal
Phase monitor LED on3-phase monitor - phases OK

All KeepRite Heat Pump error codes →

KeepRite code Phase monitor LED off: homeowner questions

What does KeepRite code Phase monitor LED off mean?

3-phase monitor - no call for compressor. The phase monitor LED is dark when there is no call for compressor operation. Nothing is wrong.

Is it safe to keep using my heat pump with code Phase monitor LED off?

Usually yes. Code Phase monitor LED off is normally minor, but if it keeps coming back have it checked.

Can I reset KeepRite code Phase monitor LED off myself?

You can try one reset (power off for 30 seconds, then on). If KeepRite code Phase monitor LED off comes back, the cause is still there and a licensed technician should check it.

Who can fix KeepRite code Phase monitor LED off near me?

Aurora Star Tech Inc. repairs KeepRite heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: KeepRite ICP N4H4/R4H4/WCH4/NXH5 Heat Pump Installation Instructions 428 01 5107 10, Table 3 3-Phase Monitor LED Indicators, p.6. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977