Lennox Error Code 10: Unknown device detected (Furnace)

Updated · by Aurora Star Tech Inc.

Lennox error code 10 on a furnace means: Unknown device detected. It is also called Lennox diagnostic code 10.

High severityFurnace

Homeowner? What Lennox code 10 means for you

Call a technician Your furnace is reporting: Unknown device detected. The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Lennox error code 10 mean?

Outside of commissioning, the thermostat found a device it does not know and put it in soft disable (two horizontal lines on furnace/air handler/outdoor 7-segment display; green LED 3 s on / 1 s off on damper module or EIM). S30/S40 thermostat alert code 10.

Applies to: Lennox communicating gas furnaces (e.g. SL280UHV/SL280UHNV, EL296UHV) in S30/S40 smart thermostat systems

Common causes of Lennox code 10

  • A new communicating device was added after the original setup
  • A control board was replaced and the system was not reconfigured
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Lennox models that use code 10

Show all 38 models

EL195UH040NE36BEL195UH060NE36BEL195UH080NE48CEL195UH100NE60CEL296UH045XV36BEL296UH070XV36BEL296UH090XV36CEL296UH090XV48CEL296UH090XV60CEL296UH110XV48CEL296UH110XV60CEL296UH135XV60DML180UH045E36AKML180UH045XE36AKML180UH070E36AKML180UH070E36BKML180UH070XE36AKML180UH070XE36BKML180UH090E48BKML180UH090E60CKML180UH090XE48BKML180UH110E60CKML180UH110XE60CKML180UH135E60DKSL280UH060NV36ASL280UH070V36ASL280UH080NV48BSL280UH080NV60CSL280UH090V36BSL280UH090V48BSL280UH090V60CSL280UH100NV60CSL280UH110V60CSL280UH135V60DSL297UH040NV36BSL297UH060NV36BSL297UH080NV48CSL297UH080NV60C

Other Lennox Furnace codes

CodeMeaning
3 flashesBurner failed to light or lost flame
4 flashesLow flame signal
5 flashesWatchguard - ignition retries/recycles exceeded
7 flashesPrimary or secondary limit open
8 flashesRollout switch open
9 flashesPressure switch stays open or drops out on a heat call
10 flashesWatchguard - pressure switch opened 5 times in one heat demand
11Missing device
11 flashesPressure switch stuck closed before inducer starts
12Indoor unit not detected
12 flashesFlame sensed with gas valve off
13Duplicate comfort sensor ID

All Lennox Furnace error codes →

Lennox code 10: homeowner questions

What does Lennox code 10 mean?

Unknown device detected. Outside of commissioning, the thermostat found a device it does not know and put it in soft disable (two horizontal lines on furnace/air handler/outdoor 7-segment display; green LED 3 s on / 1 s off on damper module or EIM). S30/S40…

Is it safe to keep using my furnace with code 10?

It depends on the cause. The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Lennox code 10 myself?

You can try one reset (power off for 30 seconds, then on). If Lennox code 10 comes back, the cause is still there and a licensed technician should check it.

Who can fix Lennox code 10 near me?

Aurora Star Tech Inc. repairs Lennox furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: Lennox Residential Communicating Systems Alert Code Guide (V2) 100017 (3/2023), Table 2 Alert Codes and Troubleshooting, p.8. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair