Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Majestic Gas Fireplace Error Codes

Updated · by Aurora Star Tech Inc.

13 Majestic Gas Fireplace error codes and diagnostic codes, with causes and troubleshooting steps for each. Select a code, or find your model below.

Homeowner with a gas fireplace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Majestic Gas Fireplace error codes list

CodeMeaningSeverity
1 BEEPSingle beep (confirmation)Medium
1 GREEN / 2 secPilot lockout - trial for ignitionHigh
1 REDConversion cover missingMedium
1 RED-GREEN / 2 secPilot lockout - flame lossHigh
1 RED / 2 sec (until reset)Pressure switch failure (power vent only)High
1 RED / 10 secLow batteryLow
2 BEEPSDouble beep (confirmation)Medium
2 REDSpark failHigh
2 RED / 10 secNo or low thermopile powerMedium
3 REDNo sensor signalHigh
GREEN FLASH 1/secLearning modeMedium
GREEN SOLIDAC power onMedium
NO BEEPNo beep after master switch ONHigh

Gas Fireplace troubleshooting guides

Homeowner help: Gas Fireplace Won't Light or Stay Lit

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977