Gas Fireplace: SIT 820 Nova millivolt valve: pilot will not light

Updated · by Aurora Star Tech Inc.

SIT 820 Nova millivolt valve: pilot will not light on a gas fireplace: Standing-pilot fireplace with an SIT 820 Nova millivolt valve: no pilot.

Homeowner with a gas fireplace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Fireplaces and gas logs with SIT 820 Nova MV / Millivolt Plus valves

Common causes of sit 820 nova millivolt valve: pilot will not light

  • Air in the gas line
  • Wrong inlet pressure
  • No spark: piezo wire, electrode or piezo igniter
  • Safety interlock still engaged after turning OFF
  • Pilot adjustment closed, gas shut-off closed, pilot orifice or tube blocked
  • Defective spill switch (gravity-vented Millivolt systems)

How to fix sit 820 nova millivolt valve: pilot will not light: step by step

  1. Press the piezo and look for a spark at the pilot hood. None: check the wire connection at the piezo end, electrode position, pinched or broken ignition wire, cracked porcelain on the electrode base, then replace the piezo.
  2. Turn the knob to PILOT, push in and spark. If it still will not light, realign the knob and retry.
  3. With the gas off, hold a flame at the pilot hood and push the pilot knob: if the flame bends away, there is air in the line - purge it through the inlet pressure port. If it does not bend, there is no gas flow: check the pilot adjustment screw is not closed, gas shut-offs are open and inlet supply is correct.
  4. Inlet pressure typically 7 in. w.c. natural gas / 11 in. w.c. LP (follow the appliance spec).
  5. After turning the knob to OFF, the safety interlock blocks relighting until the thermocouple cools (30 s or less).
  6. Check the pilot orifice and tube for blockage; replace the valve if all else is good.
  7. Millivolt (gravity vent) systems with a spill switch: check continuity across the spill switch; replace if open or high resistance.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Heat & Glo Gas Fireplace codes Napoleon Gas Fireplace codes Skytech Gas Fireplace codes

Source: SIT 820 Nova MV Troubleshooting Guide; SIT Gas Control Valve troubleshooting flow chart (Fireparts). Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.