Majestic Gas Fireplace: Check gas pressure at the valve
Check gas pressure at the valve on a Majestic gas fireplace: Reading inlet and outlet pressure on either control.
Applies to: DVBL7 series
How to fix check gas pressure at the valve: step by step
- Back the captured screw out 2 to 3 turns and push the gauge tubing over the test point
- Run the unit on high
- Millivolt: HI/LO knob at HI for maximum pressure
- After reading, tighten the screw firmly (do not over-torque) and leak-check the test point
If the unit shows an error code, look it up: Majestic Gas Fireplace codes
Source: Majestic DVBL7 Series Installation and Operating Instructions, p. 24, p. 32. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.