Majestic Gas Fireplace: Signature Command: pilot lockout (green or red-green flash)

Updated · by Aurora Star Tech Inc.

Signature Command: pilot lockout (green or red-green flash) on a Majestic gas fireplace: LED flashes every 2 seconds and the fireplace will not start.

Homeowner with a gas fireplace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: 300DVBLN/PSC7, 400DVBLN/PSC7, 500DVBLN/PSC7 (Signature Command)

Common causes of signature command: pilot lockout (green or red-green flash)

  • Pilot would not light within the spark time (green)
  • Pilot lost three times in a row (red-green)

How to fix signature command: pilot lockout (green or red-green flash): step by step

  1. Turn the master switch OFF, then ON to reset
  2. Press ON again and watch the pilot
  3. If it locks out again after several tries, turn the master switch OFF and work through the spark / sensor / gas checks
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Majestic Gas Fireplace codes

Source: Majestic DVBL7 Series Installation and Operating Instructions, p. 38, p. 47. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.